AWWA ACE63039 PDF

AWWA ACE63039 PDF

Name:
AWWA ACE63039 PDF

Published Date:
06/01/2006

Status:
Active

Description:

Unified Plant Process Control: Merging Two HMI/PLC Control Systems for a Membrane Plant and a Conventional Plant

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The city of Jackson, Mississippi, is served by two surface water treatment plants: the 25- million-gallon-per-day (mgd) O.B. Curtis plant; and, the 42-mgd J.H. Fewell plant. To meet increasing water demands and future water quality regulations, the city is expanding the O.B. Curtis facility to 50 mgd with the addition of a new 25 mgd ultrafiltration (UF) membrane facility. In addition to the onsite addition of the UF membrane plant, improvements include: expansion of the raw water pump station; modifications to the chemical systems and sedimentation basins; new ultraviolet (UV) disinfection for the conventional filters; addition of a second clear well; and, new conventional plant human machine interface/programmable logic controller (HMI/PLC) control system, high-service pump station, and closed circuit television security system. Since the UF membrane facility will treat coagulated/flocculated water and then be pumped to the new clear well, controlling the raw water flow and chemical feed addition prior to its reaching the membrane system is critical. This paper demonstrates the difficulty of incorporating the UF membrane plant instrumentation with the overall conventional plant supervisory control and data acquisition (SCADA) system. To avoid problems in the construction phase, it was essential that consideration be given during the design phase to process design, construction sequencing, and conventional plant HMI/PLC control systems design. Consideration also had to be given to merging the new stand-alone HMI/PLC UF membrane plant control system with the new conventional plant HMI/PLC control system, thus forming a single plant-wide control system. Because the UF membrane operation relies on proper raw water flow rates and dosing of chemicals, responsibility for control of these systems belongs to the UF membrane manufacturer. This paper provides insight into the decision making process of the design team as they worked together with the UF membrane system supplier to incorporate the new UF membrane control system into the overall conventional plant control system.
Edition : Vol. - No.
File Size : 1 file , 230 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 5
Published : 06/01/2006

History


Related products

AWWA ACE63004
Published Date: 06/01/2006
Arc Flash in the Water/Wastewater Industry: No Longer an Emerging Issue
$7.2
AWWA ACE63015
Published Date: 06/01/2006
Jordan River Return Flow Study
$7.2
AWWA ACE63023
Published Date: 06/01/2006
The Conserve Florida Web Application
$7.2
AWWA ACE63078
Published Date: 06/01/2006
Effect of pH, In-Situ Hydroxide Formation, and Competing Ions on As(III/V) Adsorption During Coagulation with Ferric Chloride
$7.2

Best-Selling Products

Paper Coating Additives
Published Date: 04/01/1995
$22.2
The Mechanics of Rollers
Published Date: 01/01/1996
$27
The Mechanics of Winding
Published Date: 06/01/1994
$24.3