AWWA ACE65154 PDF

AWWA ACE65154 PDF

Name:
AWWA ACE65154 PDF

Published Date:
06/01/2007

Status:
Active

Description:

Storage Reservoir Water Quality Improvements Using CFD

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The objective of this project is to improve reservoir mixing while minimizing construction inside two reservoirs. The reservoirs, which are owned and operated by EPCOR Water Services Inc. in Edmonton, Alberta, Canada are arranged in parallel between the filters and the distribution pump station at the E.L. Smith Water Treatment Plant. Flow through the reservoirs is by gravity. Computational fluid dynamics (CFD) analysis has been used to identify stagnant regions and to develop a strategy to eliminate them. The CFD software used in this analysis is Fluent. Mixing effectiveness can be evaluated through examination of steady state velocity contours, but a more quantitative assessment has been completed using Fluent's multi-species modelling capabilities. Time dependent solutions produced concentration contour plots that can be used individually, or compiled into an animation sequence, to observe the mixing process. Also measurements of influent concentration at the effluent can be used to compare reservoir performance over the full range of anticipated flow rates. These results could also be used to compare with tracer study results. Due to differences in their configuration, two different approaches to improve mixing have been proposed, but not yet implemented. In one case, the reservoir is square with its influent and effluent located at adjacent corners and there is a partial internal wall along the reservoir centerline prevented flow short-circuiting. Installation of nine short wall sections between columns is sufficient to promote cross-channel mixing and eliminate regions of flow stagnation for all flow conditions. In the second case, the reservoir is very long and narrow with the influent and effluent located at adjacent corners, leading to flow short-circuiting. Since the influent has very little kinetic energy, the ultimate solution involved constructing an internal wall with small openings to promote plug flow along the reservoir length and another to effectively relocate the effluent. Flow stagnation is eliminated, but there is greater uncertainty with the proposed solution because of the low velocities. CFD is an excellent prototyping tool to cost effectively examine various possibilities to improve reservoir mixing. The results can often be used to guide the development of innovative and cost-effective solutions, but sometimes uncertain results indicate that a conservative design approach is appropriate. Includes 4 references, tables, figures.
Edition : Vol. - No.
File Size : 1 file , 5.2 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 16
Published : 06/01/2007

History


Related products

AWWA ACE65256
Published Date: 06/01/2007
LCR Sampling in Relation to Public Health Goals for Lead
$7.2
AWWA ACE65090
Published Date: 06/01/2007
Asset Management Best Practices: The Rehabilitation of the LVVWD Distribution Network Using CARE-W
$7.2
AWWA ACE65616
Published Date: 06/01/2007
Getting Ready for Climate Change Implications to the Western U.S.
$7.2
AWWA ACE65459
Published Date: 06/01/2007
Building Shared Understanding: Effective Public Consultation
$7.2

Best-Selling Products

CAN/CSA-ISO 1/5/1996
Published Date: 02/01/2005
Acoustics - Description, Measurement and Assessment of Environmental Noise - Part 1: Basic Quantities and Assessment Procedures (Adopted ISO 1996-1:2003, second edition, 2003-08-01)
CAN/CSA-ISO 10001-08 (R2017)
Published Date: 02/01/2008
Quality Management - Customer Satisfaction - Guidelines for Codes of Conduct for Organizations (Adopted ISO 10001:2007, first edition, 2007-12-01)
$34.5
CAN/CSA-ISO 10001:20
Published Date: 05/01/2020
Quality management - Customer satisfaction - Guidelines for codes of conduct for organizations (Adopted ISO 10001:2018, second edition, 2018-07)
$42
CAN/CSA-ISO 10002-04 (R2009)
Published Date: 09/01/2004
Quality Management - Customer Satisfaction - Guidelines for Complaints Handling in Organizations (Adopted ISO 10002:2004, first edition, 2004-07-01)
$37.8
CAN/CSA-ISO 10002:20
Published Date: 05/01/2020
Quality management - Customer satisfaction - Guidelines for complaints handling in organizations (Adopted ISO 10002:2018, third edition, 2018-07)
$48
CAN/CSA-ISO 10003-08 (R2017)
Published Date: 02/01/2008
Quality Management - Customer Satisfaction - Guidelines for Dispute Resolution External to Organizations (Adopted ISO 10003:2007, first edition, 2007-12-01)
$48.9