AWWA ACE65169 PDF

AWWA ACE65169 PDF

Name:
AWWA ACE65169 PDF

Published Date:
06/01/2007

Status:
Active

Description:

Reusing and Converting Existing Plant Infrastructure

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
This powerpoint presentation outlines an expansion project at the E.L. Smith Water Treatment Plant (WTP) in Edmonton, Alberta, Canada. Concept development included a number of innovative ideas that would help achieve the mandated capacity increase while reusing parts of the existing process and converting their function. The conceptual design for the current upgrade identified the following criteria: expansion to increase net firm capacity to 400 ML/d with the capacity to increase to 600 ML/d in the future; provide reliability, redundancy, robustness and ease of operation and maintenance; reuse existing infrastructure as much as possible; increase raw water intake and pumping capacity; provide raw water feed to clarifier C3; increase clarification capacity by converting and reusing Clarifier C3 as a turbidity removal clarifier; increase hydraulic capacity; increase filtration capacity; increase disinfection capacity; and, increase chemical feed capacity. Further topics outlined include: raw water supply and pipeline; clarifiers; filters; and, chemical systems. Includes tables, figures.
Edition : Vol. - No.
Number of Pages : 36
Published : 06/01/2007

History


Related products

AWWA ACE65574
Published Date: 06/01/2007
Operational Mitigation Strategies to Deal with Arsenic Leaching during Adsorption Treatment
$7.2
AWWA ACE65267
Published Date: 06/01/2007
Effect of Time and pH History on Arsenic Removal by Granular Iron Hydroxide Media
$7.2
AWWA ACE65582
Published Date: 06/01/2007
From Source Water Assessments to Source Water Protection: The U.S. Experience
$7.2
AWWA ACE65297
Published Date: 06/01/2007
Measuring Affordability
$7.2

Best-Selling Products

IAPMO 150-2007
Published Date: 2007
Vacuum Sewage, Grease Waste and/or Condensate Collection Systems
$19.5
IAPMO 2012 Green Plumbing and Mechanical Code Supplement
Published Date: 04/01/2012
2012 Green Plumbing and Mechanical Code Supplement - For Use with All Codes
$18.3
IAPMO /ANSI/CAN/ASSE 1055-2020
Published Date: 2020
Performance Requirements for Chemical Dispensers with Integral Backflow Protection
$13.5
IAPMO /ANSI/CAN/ASSE 1055-2020
Published Date: 2023
Performance Requirements for Chemical Dispensers with Integral Backflow Protection
$13.5
IAPMO /ANSI/CAN/ASSE 1103-2024
Published Date: 2024
Performance Requirements for Pilot Operated Water Pressure Reducing Valves for Potable Water
$13.5
IAPMO /ANSI/CAN/ISO 30500:2019
Published Date: 2019
Non-sewered sanitation systems - Prefabricated integrated treatment units - General safety and performance requirements for design and testing (ISO 30500:2018, IDT)
$66