This powerpoint presentation begins by providing background information on Tampa Bay Water and the Lithia Water Treatment Plant in Hillsborough County, Florida. The presentation presents a study on treatment alternatives for H<sub>2</sub>S
removal while meeting water quality (WQ) standards.
Parameters of greatest concern include:
H<sub>2</sub>S: < 0.1 mg/L; and,
turbidity: < 1.0 NTU. The study also
evaluated treatment alternatives that
consistently met the above criteria. Process chemistry is presented, along with procedures concerning pilot plant configurations, experimental plan - membranes, bench tests: H<sub>2</sub>S removal by chlorine; Schematic: Cl<sub>2</sub>-oxidation - UF; Schematic: Bio-oxidation - UF; Conclusions related to treated water quality
and membrane cleaning interval; Integration of Membrane Alternatives into
Existing Treatment Process; and, Criteria for Membrane Alternative
Rankings. Ranking Results were:
Biological Oxidation followed by UF;
Chlorine Oxidation followed UF; and,
Ozone followed by BAC.