Description:

Methods for Design of Chlorine Contactors for Drinking Water Treatment. Kinetic and Hydraulic Considerations for Disinfection Efficiency Estimation

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The present study concerns the possible methods of evaluating the performance of storage chlorine contactors for water treatment and gives some ideas for their design. Improvement of the performance of already existing disinfection contactors can be as well carried out. These chlorination tanks are used mainly as a regulator between the water treatment plant and the distribution network which has variable flowrate conditions. In addition, these storage tanks are reactors for the disinfection process as they create a sufficient contact time between water and the disinfectant.
File Size : 1 file
ISBN(s) : 0898677130
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 17
Published : 01/01/1993

History


Related products

AWWA ACE91022
Published Date: 01/01/1991
CT Compliance Strategies: Three Case Studies
$7.2
AWWA ACE93157
Published Date: 01/01/1993
The C-T Concept and Modifications to Improve Detention Times
$7.2
AWWA ACE93137
Published Date: 01/01/1993
Radon in Drinking Water: Is There a Health Risk?
$7.2
AWWA ACE93131
Published Date: 01/01/1993
The Effect of Biodegradable Organic Carbon Removal on the Bacterial Regrowth Potential and Disinfection By-Product Formation of Ozonated Water
$7.2

Best-Selling Products

AAMI/IEC 601219E
Published Date: 03/27/2012
Erratum for Medical electrical equipment - Part 2-19: Particular requirements for basic safety and essential performance of baby incubators
Free Download
AAMI/IEC 601220E
Published Date: 03/27/2012
Erratum for Medical electrical equipment - Part 2-20: Particular requirements for basic safety and essential performance of transport incubators
Free Download
AAMI/IEC 60601-1-12:2016/A1:2021
Published Date: 03/20/2022
Amendment 1, Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performan - Collateral standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment
$38.7
AAMI/IEC 60601-1-12:2016 & A1:2021
Published Date: 08/22/2022
Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance - Collateral standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment CONSOLIDATED EDITION
$85.2
AAMI/IEC 60601-1-12:2016
Published Date: 10/06/2016
Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performan - Collateral standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment
$82.5
AAMI/IEC 60601-1-2:2007/(R)2012
Published Date: 05/15/2007
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests
$56.1