AWWA ACE95135 PDF

AWWA ACE95135 PDF

Name:
AWWA ACE95135 PDF

Published Date:
01/01/1995

Status:
Active

Description:

Stand-By Charges & Fire Sprinkler Systems

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
There are a number of water supply issues that impact the installation of a fire sprinkler system in a building. Not the least of which is the issue of stand-by charges levied against properties with fire sprinkler systems due to their potential for water use. The common thread that runs through all discussions pertaining to fire sprinkler systems is that these systems use large amounts of water and should be taxed for it. The author believes that these misconceptions can be changed with a better understanding of how fire sprinkler systems are designed and how they operate in a fire. This paper discusses six basic steps used in determining the total water flow demand of a fire sprinkler system. These steps include: selecting the installation standard; selecting the correct classification (light hazard, ordinary hazard group 1, ordinary hazard group 2, extra hazard group 1, extra hazard group 2); determining the location and size of the building; identifying the location and size of the hydraulically most remote area in the system; designating a minimum density of water to be delivered over the floor of the most remote area; and determining the number of sprinklers that will operate. The author concludes that building owners that opt for, or that are required to install sprinklers per the building code should not be assessed an additional fee. Under the current practice, the owner of the building that is not sprinklered requires the highest water demand, putting the greatest strain on the capabilities of the water utility and pays the least. Therefore, stand-by charges, if they must be enacted, should cover all buildings in the water district and be assessed contingent on the fire flow demand of the building.
File Size : 1 file
ISBN(s) : 0898678358
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 5
Published : 01/01/1995

History


Related products

AWWA ACE95163
Published Date: 01/01/1995
Use of Mathematical and Physical Mixing and Water Quality Models in the Design and Operation of Tanks and Reservoirs
$7.2
AWWA ACE95161
Published Date: 01/01/1995
"We Commit..." A Presentation of the Partnering Approach to Project Management of the Tri-County Water Supply Project
$7.2
AWWA ACE95159
Published Date: 01/01/1995
Partnering for the Construction of the Haworth Treatment Plant Maintenance Facility
$7.2
AWWA ACE95152
Published Date: 01/01/1995
Linking SCADA With Network Simulation
$7.2

Best-Selling Products

IEEE/NACE 2655
Published Date:
IEEE/NACE Draft Standard Practice - Atmospheric Above Grade Inspection and Assessment of Corrosion on Steel Electrical Transmission, Distribution, and Substation Structures
IEEE/NACE P2655
Published Date: 01/01/2018
IEEE/NACE Approved Draft Standard - Atmospheric Above Grade Inspection and Assessment of Corrosion on Steel Electrical Transmission, Distribution, and Substation Structures
$17.1