AWWA D110-95 PDF

AWWA D110-95 PDF

Name:
AWWA D110-95 PDF

Published Date:
01/01/1995

Status:
Active

Description:

Wire-Wound Circular Prestressed Concrete Water Tanks (includes addendum D110a-96 and 2001 erratum)

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$42
Need Help?
This standard covers current recommended practice for the design, construction, inspection, and maintenance of wire- and strand-wound, circular, prestressed concrete water containing structures with the following four types of core walls: cast-in-place concrete with vertical prestressed reinforcement; shotcrete with a steel diaphragm; precast concrete with a steel diaphragm; cast-in-place concrete with a steel diaphragm. This standard does not cover bonded or unbonded horizontal tendons for prestressed reinforcement of the tank wall, floor, or roof. This standard applies to containment structures for use with potable water or raw water of normal temperatures and pH commonly found in drinking water supplies. It is not intended for use in the design of containment structures for highly aggressive waters or high-temperature waters without special consideration being given to their effects on the structure; nor is it intended that the standard be used for the design of structures for wastewater, bulk dry storage, chemical storage, or storage of slurries. This second edition of the standard has been edited throughout and includes revisions to standard definitions and terms. Provisions for earthquake-induced forces, formerly attached to the standard as appendix A, have been incorporated into the standard as Sec. 4 and updated in accordance with experience and current practice. Finally, 15 technical revisions to the standard reflect current thinking and construction practices.

This addendum to ANSI/AWWA D110-95 Standard for Wire- and Strand-Wound Circular-Prestressed Concrete Water Tanks revises or replaces Sec. 4.3.1(4); Sec. 4.3.2; and Sec. 4.5.3, Equation 4.24.


ANSI : ANSI Approved
File Size : 2 files , 27 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Published : 01/01/1995

History

AWWA D110-13 (R2018)
Published Date: 12/01/2013
Wire- and Strand-Wound, Circular, Prestressed Concrete Water Tanks
$42
AWWA D110-04
Published Date: 02/01/2005
Wire- and Strand-Wound, Circular, Prestressed Concrete Water Tanks
$42
AWWA D110-95
Published Date: 01/01/1995
Wire-Wound Circular Prestressed Concrete Water Tanks (includes addendum D110a-96 and 2001 erratum)
$42

Related products

AWWA D115-20
Published Date: 07/01/2020
Tendon-Prestressed Concrete Water Tanks
$42
AWWA D130-11 (R2019)
Published Date: 11/01/2011
Goemembrane Materials for Potable Water Applications
$42
AWWA D110-13 (R2018)
Published Date: 12/01/2013
Wire- and Strand-Wound, Circular, Prestressed Concrete Water Tanks
$42

Best-Selling Products

FM Approvals 1011/1012/1013:2020
Published Date: 12/01/2020
Examination Standard for Deluge and Preaction Sprinkler Systems
$15
FM Approvals 1011/1012/1013
Published Date: 09/01/2009
Deluge and Preaction Sprinkler Systems
$15
FM Approvals 1020:2020
Published Date: 12/01/2020
Examination Standard for Automatic Water Control Valves
$15
FM Approvals 1020
Published Date: 04/01/2007
Automatic Water Control Valves
$15
FM Approvals 1021:2020
Published Date: 12/01/2020
Dry Pipe Valves
$15
FM Approvals 1021
Published Date: 11/01/1973
Dry Pipe Valves
$15