AWWA DSS60345 PDF

AWWA DSS60345 PDF

Name:
AWWA DSS60345 PDF

Published Date:
09/29/2004

Status:
Active

Description:

Optimizing Use of Conventional and Directional Flushing Techniques Using Computer Models

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
This paper discusses how water distribution system computer models can be used to assess and improve the effectiveness of conventional flushing programs. Using the model, flow rates for each hydrant are simulated to predict pipeline flow velocities. Model output is then analyzed to identify pipeline segments that do not achieve the target flushing velocity. The target flushing velocity can vary from system to system and may depend on the flushing program objectives. The length of pipeline segments that do not achieve the desired flushing velocity compared to the total length of pipeline in the system provides an estimate of the efficiency of the conventional hydrant flushing program. The model can also be used to develop specific procedures for improving the flushing effectiveness by increasing the flow velocity in areas of the system that would not otherwise achieve the desired flushing velocity. For example, the model can predict how opening additional hydrants and/or strategically closing valves could increase flow velocities in certain pipes. Directional or other special flushing procedures can be implemented based on the model results, to improve flushing effectiveness for specific areas of the system. The primary advantage of this system flushing approach is that the utility only performs more costly flushing techniques in areas of the system where they are required to achieve flushing velocity goals. In addition to optimizing pipeline flow velocities to maximize the flushing program effectiveness, the hydraulic model can be used to predict minimum system pressures that will occur during the flushing event, to help ensure that minimum system pressure requirements are maintained, and to establish key pressure monitoring locations. In addition, the model can be used to help establish flushing routes based on normal flow directions. Includes 3 references, table, figures.
Edition : Vol. - No.
File Size : 1 file , 330 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 9
Published : 09/29/2004

History


Related products

AWWA DSS60311
Published Date: 09/29/2004
Managing Today's Workforce
$7.2
AWWA DSS60315
Published Date: 09/29/2004
Financial Planning for the Replacement/Rehabilitation of Water Infrastructure
$7.2
AWWA DSS60316
Published Date: 09/29/2004
Proactive Planning for Water Main Replacement/Rehabilitation for the City of Chicago
$7.2
AWWA DSS60321
Published Date: 09/29/2004
Water Distribution Emergency Plans
$7.2

Best-Selling Products

NETA ATS-2009
Published Date: 02/19/2009
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2009 Edition
$247.5
NETA ATS-2013
Published Date: 2013
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2013 Edition
$82.5
NETA ATS-2017
Published Date: 2017
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2017 Edition (Errata Included)
$87
NETA ATS-2021
Published Date: 09/18/2020
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2021 Edition
$87
NETA ECS-2020
Published Date: 2020
Standard for Electrical Commissioning Specifications for Electrical Power Equipment and Systems, 2020 Edition
$57
NETA ECS-2024
Published Date: 2024
Standard for Electrical Commissioning Specifications for Electrical Power Equipment & Systems, 2024 Edition
$62.7