AWWA MTC61115 PDF

AWWA MTC61115 PDF

Name:
AWWA MTC61115 PDF

Published Date:
03/01/2005

Status:
Active

Description:

Application of Integrated Membrane Systems to Develop an Alternative Water Supply in Central Florida

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The St. Johns River Water Management District (SJRWMD) and CH2M HILL conducted an extensive pilot study involving the use of integrated membrane systems to produce potable water from the St. Johns River. The study identified treatment processes and costs involved in using the St. Johns River as an alternative water supply. This source is one alternative being evaluated to offset a large water supply deficit projected in eastern central Florida. The raw water source for the pilot study was Lake Monroe in Sanford, Florida. This lake is part of the St. Johns River system, and is characteristic of typical Florida surface water with low turbidity and high dissolved organics. In addition, the lake periodically becomes brackish from saline groundwater inflow during low rainfall periods. Prior to testing, a preliminary raw water characterization study identified the treatment requirements necessary for St. Johns River water and a potential treatment facility to be located in the reach between Titusville and DeLand on the St. Johns River. The basis of this study was to evaluate pretreatment technologies that would sufficiently reduce the organic and turbidity levels in the water (e.g., coagulation, clarification, and filtration) so that effective salt removal could be conducted with reverse osmosis (RO) membranes. The purpose of this study was to demonstrate the treatability of this source water, identify the appropriate technology and basic design parameters for treatment, and determine both the capital and operational costs for this potential facility. The intent is that the information in this report will assist an entity in implementing a surface water treatment facility in this reach of the St Johns River and facilitate the next step for a water supply project of this type. The findings of this study are that the source water in this reach of the St. Johns River is treatable and can be used as a source for potable drinking water. All of the technologies identified and selected by the stakeholders for testing in this study demonstrated feasibility and can be recommended for use on this water.
Edition : Vol. - No.
File Size : 1 file , 360 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 10
Published : 03/01/2005

History


Related products

AWWA MTC61112
Published Date: 03/01/2005
Good Water, Aggressive Flux, and Challenging Implementation
$7.2
AWWA MTC61128
Published Date: 03/01/2005
Predicting Performance of Membrane Systems: Neural Networks
$7.2
AWWA MTC61167
Published Date: 03/01/2005
A New Approach to Low Pressure Membrane Filtration - Direct Coagulation Reduces Costs
$7.2
AWWA MTC61181
Published Date: 03/01/2005
Three Liters of Soda in a Two Liter Bottle
$7.2

Best-Selling Products

ASQ A8402-1994
Published Date: 01/01/1994
ANSI/ISO/ASQ Standard - Quality Management and Quality Assurance - Vocabulary (Revision and Redesignation of ANSI/ASQ A3-1987)
$10.5
ASQ E1-1996
Published Date: 01/01/1996
Quality Program Guidelines for Project Phase of Nonnuclear Power Generation Facilities
$11.1
ASQ E4-1994
Published Date: 01/01/1994
Specifications and Guidelines for Quality Systems for Environmental Data Collection and Environmental Technology Programs
$13.2
ASQ E4:2014 (R2019)
Published Date: 05/01/2019
Quality management systems for environmental information and technology programs— Requirements with guidance for use
$29.7
ASQ M1-1996
Published Date: 02/26/1996
American National Standard for Calibration Systems
$17.7
ASQ Q10011-1994 Series
Published Date: 01/01/1994
ANSI/ISO/ASQ Standard - Guidelines for Auditing Quality Systems: 1994 Series - Includes Q10011-1, Q10011-2, and Q10011-3
$15