AWWA WQTC56973 PDF

AWWA WQTC56973 PDF

Name:
AWWA WQTC56973 PDF

Published Date:
11/01/2002

Status:
Active

Description:

Appraising the Utilization of GAC Pore Volume With Respect to Depth in Full-Scale Contactors

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
This research investigates pore volume losses and total organic carbon (TOC) adsorption in virgin and reactivated granular activated carbon (GAC) used during full-scale water treatment. Pore volume changes were studied at several depths within each contactor. Pore volume at upper depths was lost over a wide range of pore sizes, whereas pore volume losses at middle and lower depths occurred primarily in the micropores. Adsorptive forces are inherently strongest in micropores because both pore walls exert an attractive potential on natural organic matter (NOM). Correspondingly, NOM that reached the middle and lower depths would inherently be characterized by a lower affinity for the GAC surface, necessitating double-wall adsorption. Furthermore, the upper depths of the reactivated GACs were characterized by considerable pore volume losses in the 100-500¿ range, where adsorption would inherently represent single-wall adsorption of highly adsorbable molecules. The comprehensive data set has facilitated a mass/volume balance that compared computed volume of NOM removed through the GAC contactors, (monitored via TOC influent and effluent), versus pore volume lost in pores <500¿ width (monitored via argon adsorption tests). These two volumes essentially equaled one another, and this was observed for each of the five loading conditions that were tested herein. Includes 19 references, table, figures.
Edition : Vol. - No.
File Size : 1 file , 410 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 24
Published : 11/01/2002

History


Related products

AWWA WQTC56937
Published Date: 11/01/2002
Comparison of Customer Sensitivity to Chlorine and Satisfaction With Tap Water Quality
$7.2
AWWA WQTC56980
Published Date: 11/01/2002
Inactivation of E. coli and MS2 Coliphage With Ultrasound and Chlorine
$7.2
AWWA WQTC57026
Published Date: 11/01/2002
Water Industry Laboratory Response to Contamination Threats
$7.2
AWWA WQTC57086
Published Date: 11/01/2002
Rejection of Heavy Metals by Reverse Osmosis Membranes
$7.2

Best-Selling Products

ANSI/IEST/ISO 14644-12
Published Date: 08/01/2018
Cleanrooms and associated controlled environments - Part 12: Specifications for monitoring air cleanliness by nanoscale particle concentration
$23.4
ANSI/IEST/ISO 14644-16
Published Date: 05/01/2019
Cleanrooms and associated controlled environments - Part 16: Code of practice for improving energy efficiency in cleanrooms and clean air devices
$65.7
ANSI/IEST/ISO 14644-18: 2023
Published Date: 10/20/2023
Cleanrooms and Associated Controlled Environments - Part 18: Assessment of Suitability of Consumables
$65.7
ANSI/IEST/ISO 14644-4
Published Date: 11/01/2022
Cleanrooms and associated controlled environments - Part 4: Design, construction and start-up
$73.5