Description:

Assessment of Two Types of DAF Clarification: Conventional and High Rate

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
A pilot study was conducted from September through mid-November 2003 to assess two types of dissolved air flotation (DAF) clarification processes, followed by filtration, and establish design criteria for a proposed water treatment plant in Peekskill, New York. The DAF processes examined during this pilot study were conventional DAF treatment and proprietary high rate DAF treatment (AquaDAF", licensed by Infilco Degremont from Rictor Oy, Finland). This paper presents an overview of the pilot study, including details on the pilot facilities and criteria used to measure the performance of the process trains, and an evaluation of results. The conventional DAF process train included in-line static mixing and two-stage flocculation, followed by dissolved air flotation. The high rate DAF process train included mechanical mixing and three-stage flocculation, followed by dissolved air flotation. Following dissolved air flotation, both process trains were connected to a common set of filters, operated in parallel. Two loading rates were tested for each DAF process during the pilot study, 6 and 7.5 gpm/sf for conventional DAF and 12 and 16 gpm/sf for high rate DAF. Various filter loading rates were also tested. Filters with typical depth media configurations were run at 4, 5, and 6 gpm/sf. Filters with deep bed media configurations were run at 6 and 8 gpm/sf. The pilot data confirmed that both the conventional DAF and high rate DAF processes would provide high quality finished water (low filtered water turbidity and high particle removal) while maintaining adequate filter run lengths. Filtered water turbidity was consistently below 0.1 NTU, log particle removal ranged between 1.1 and 2.8 for optimized runs, and unit filter run volumes consistently exceeded the pilot goal of 7,500 gal/sf. Additionally, concentrations of iron and manganese in the filtered water were frequently undetectable and reliably below 0.02 mg/L and TOC removal ranged from 41% - 58%. Includes tables, figures.
Edition : Vol. - No.
File Size : 1 file
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 11
Published : 11/15/2004

History


Related products

AWWA ACE59870
Published Date: 06/17/2004
Challenging the Limits of High-Rate DAF Technology
$7.2
AWWA WQTC60548
Published Date: 11/15/2004
The Detection of Blue-Green Algal Toxins and Taste and Odor Compounds in Water Using DNA Based Technology
$7.2
AWWA WQTC60549
Published Date: 11/15/2004
Analysis of Algal Toxins by LC/MS/MS
$7.2
AWWA WQTC60550
Published Date: 11/15/2004
Breaking New Ground: Large Membrane Water Plants
$7.2

Best-Selling Products