This powerpoint presentation begins by providing background information on the integrity monitoring methodology for microfiltration/ultrafiltration (MF/UF) membranes. The objectives of the study were to have a decision-aid tool for operators that:
gives them the integrity level of their plant without having to disconnect all the
modules; and, that
indicates whether the measured level effects plant effectiveness, requiring
immediate repair. Methods included:
developing a model that uses the air flow rate throughout a defect during the
air pressure test for predicting the microbial Log Removal Value (LRV) of the unit;
conducting challenge tests with MS2 phages with various calibrated defects
on the membrane fibers at bench-scale in order to validate the model and the selected
assumptions; and,
evaluating the validity of the model at full-scale. Includes figures.
| Edition : | Vol. - No. |
| File Size : | 1
file
, 1.7 MB |
| Note : | This product is unavailable in Ukraine, Russia, Belarus |
| Number of Pages : | 29 |
| Published : | 11/01/2007 |