CEI EN 62271-107 PDF

CEI EN 62271-107 PDF

Name:
CEI EN 62271-107 PDF

Published Date:
02/01/2013

Status:
[ Revised ]

Description:

High-voltage switchgear and controlgear Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$58.2
Need Help?
W/D S/S BY CEI EN IEC 62271-107

Subclause 1.1 of IEC 62271-1:2007 is not applicable, and is replaced as follows.

This part of IEC 62271 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses designed so as to be capable of:

– breaking, at the rated recovery voltage, any load or fault current up to and including the rated short-circuit breaking current;

– making, at the rated voltage, circuits to which the rated short-circuit breaking current applies.

They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits.

Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher.

NOTE 1 In this standard the term "fuse" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity.

This standard applies to fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. Comparison with other existing switching devices is provided in Clause 8.

NOTE 2 Other circuit-switchers exist; see reference [1]1.

Devices that require a dependent manual operation are not covered by this standard.

Fuses are covered by IEC 60282-1.

Earthing switches forming an integral part of a circuit-switcher are covered by IEC 62271-102.

Installation in enclosure, if any, is covered either by IEC 62271-200 or by IEC 62271-201.

1 Numbers between brackets refer to the Bibliography.


Edition : 13
File Size : 1 file , 530 KB
Number of Pages : 54
Published : 02/01/2013

History

CEI EN IEC 62271-107
Published Date: 01/01/2020
High-voltage switchgear and controlgear Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
$35.1
CEI EN 62271-107
Published Date: 02/01/2013
High-voltage switchgear and controlgear Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
$58.2

Related products

CEI EN 60317-36
Published Date: 06/01/2014
Specifications for particular types of winding wires Part 36: Solderable polyesterimide enamelled round copper wire, class 180, with a bonding layer
75.60 61.00 you save 14.60
CEI EN 61947-2
Published Date: 11/01/2002
Electronic projection - Measurement and documentation of key performance criteria - Part 2: Variable resolution projectors
$22.5
CEI CLC/TS 50131-11
Published Date: 11/01/2013
Alarm systems - Intrusion and hold-up systems Part 11: Hold-up devices
$25.8

Best-Selling Products

Q52-98 Lockout/Tagout Video
Published Date: 03/15/1998