CEI EN IEC 63045 PDF

CEI EN IEC 63045 PDF

Name:
CEI EN IEC 63045 PDF

Published Date:
02/01/2021

Status:
[ Active ]

Description:

Ultrasonics - Non-focusing short pressure pulse sources including pneumatic and ballistic pressure pulse sources - Characteristics of fields

Publisher:
Comitato Elettrotecnico Italiano

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
cei-en-iec-63045_2752280

Choose Document Language:
39.30 €
Need Help?

This document is applicable to

– therapy equipment using extracorporeally induced non-focused or weakly focused pressure pulses;

– therapy equipment producing extracorporeally induced non-focused or weakly focused mechanical energy,

where the pressure pulses are released as single events of duration up to 25 μs.

This document does not apply to

– therapy equipment using focusing pressure pulse sources such as extracorporeal lithotripsy equipment;

– therapy equipment using other acoustic waveforms like physiotherapy equipment, low intensity ultrasound equipment and HIFU/HITU equipment.

This document specifies

– measurable parameters which are used in the declaration of the acoustic output of extracorporeal equipment producing a non-focused or weakly focused pressure pulse field,

– methods of measurement and characterization of non-focused or weakly focused pressure pulse fields.

NOTE 1 The parameters defined in this document do not – at the time of publication – allow quantitative statements to be made about clinical efficacy and possible hazard. In particular, it is not possible to make a statement about the limits for these effects.

NOTE 2 Figure B.1 to Figure B.10 and Figure 2 to Figure 4 are useful to understand the geometry of the field applied in this document.

This document has been developed for equipment intended for use in pressure pulse therapy, for example therapy of orthopaedic pain like shoulder pain, tennis elbow pain, heel spur pain, muscular trigger point therapy, lower back pain, etc. It is not intended to be used for extracorporeal lithotripsy equipment (as described in IEC 61846), physiotherapy equipment using other waveforms (as described in IEC 61689) and HIFU/HITU equipment (see IEC 60601-2-62 and IEC TR 62649).


Edition : 21
File Size : 1 file , 5.9 MB
Number of Pages : 70
Published : 02/01/2021

History


Related products

CEI IEC/TS 62933-3-1
Published Date: 02/01/2021
Electrical energy storage (EES) systems Part 3-1: Planning and performance assessment of electrical energy storage systems - General specification
33.30 €
CEI EN IEC 61547
Published Date: 06/01/2023
Equipment for general lighting purposes - EMC immunity requirements
15.90 €
CEI EN 50299-2
Published Date: 04/01/2016
Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Part 2: Dry-type cable terminations
8.10 €
CEI CLC/TS 50131-2-9
Published Date: 12/01/2017
Alarm systems - Intrusion and hold-up systems Part 2-9: Intrusion detectors - Active infrared beam detectors
23.70 €

Best-Selling Products

HIR FTV RP 2007
Published Date: 03/01/2018
In-service Inspection of Aboveground Atmospheric Fiberglass Reinforced Plastic Tanks and Vessels
69.00 €
HIR FTV RP 2007
Published Date: 01/03/2023
In-service Inspection of Aboveground Atmospheric Fiberglass Reinforced Plastic Tanks and Vessels, Recommended Practice 2007(c)
79.50 €
HIR Publication 2023
Published Date: 12/31/2023
A publication providing insights into the methods used to repair small, existing, shop-fabricated steel Above-ground, Atmospheric Pressure, Vented, Tanks designed and used for Petroleum and Non- Petroleum storage
47.70 €