DANSK DS/EN 12543-2 PDF

DANSK DS/EN 12543-2 PDF

Name:
DANSK DS/EN 12543-2 PDF

Published Date:
04/20/2021

Status:
[ Active ]

Description:

Non-destructive testing – Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing – Part 2: Pinhole camera radiographic method

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
dansk-ds-en-12543-2_2682033

Choose Document Language:
15.30 €
Need Help?

This document specifies a method for the measurement of effective focal spot dimensions above 0,1 mm of X-ray systems up to and including 1000 kV tube voltage by means of the pinhole camera method with digital evaluation. The tube voltage applied for this measurement is restricted to 200 kV for visual film evaluation and may be selected higher than 200 kV if digital detectors are used. The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular the size and the two dimensional intensity distribution as seen from the detector plane. This method compared to the others in the EN 12543 series allows to obtain an image of the focal spot and to see the state of it (e.g. cratering of the anode). This test method provides instructions for determining the effective size (dimensions) of standard (macro focal spots) and mini focal spots of industrial X-ray tubes. This determination is based on the measurement of an image of a focal spot that has been radiographically recorded with a "pinhole" technique and evaluated with a digital method. For the characterization of commercial X-ray tube types (i.e. for advertising or trade) it is advised that the specific FS (Focal spot) values of Annex A are used.


Edition : 21
File Size : 1 file , 1.4 MB
Number of Pages : 20
Product Code(s) : DS-017, DS-017
Published : 04/20/2021

History

DANSK DS/EN 12543-2
Published Date: 04/20/2021
Non-destructive testing – Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing – Part 2: Pinhole camera radiographic method
15.30 €
DANSK DS/EN 12543-2
Published Date: 08/19/2008
Non-destructive testing – Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing – Part 2: Pinhole camera radiographic method
13.20 €

Related products

DANSK DS/CLC/TR 62125
Published Date: 05/21/2008
Environmental statement specific to TC 20 - Electric cables
19.80 €
DANSK DS/EN 50500
Published Date: 08/25/2008
Measurement procedures of magnetic field levels generated by electronic and electrical apparatus in the railway environment with respect to human exposure
23.40 €
DANSK DS/ISO 24614-2
Published Date: 09/12/2011
Language resource management - Word segmentation of written texts - Part 2: Word segmentation for Chinese, Japanese and Korean
33.60 €

Best-Selling Products

AAMI 11135:1994
Published Date: 05/01/1994
Medical Devices - Validation and Routine Control of Ethylene Oxide Sterilization - Includes Errata
29.70 €
AAMI 11607:1997
Published Date: 02/24/1997
Packaging for terminally sterilized medical devices
AAMI 11663:2014
Published Date: 08/08/2014
Quality of dialysis fluid for hemodialysis and related therapies
AAMI 11737-1
Published Date: 09/01/1995
Sterilization of Medical Devices - Microbiological Methods - Part 1: Estimation of the Population of Microorganisms on Product
26.40 €
AAMI 11737-2
Published Date: 09/01/1998
Sterilization of medical devices - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process
26.40 €
AAMI 13958:2014
Published Date: 08/15/2014
Concentrates for hemodialysis and related therapies