Description:

Heat exchangers – Test procedures for establishing performance of air to air heat recovery components

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
dansk-ds-en-308_2665868

Choose Document Language:
35.70 €
Need Help?

This document specifies methods to be used for testing of air-to-air heat recovery components (HRC). The main purpose of the HRC is to exchange heat between exhaust air and supply air in order to save energy, which results in – preheat or heat, and/or – precool or cool supply air in ventilation systems or air conditioning systems. Optionally HRC can exchange air humidity between exhaust and supply air. The HRC contains the heat exchangers and all necessary features and auxiliary devices for the exchange of sensible heat and (if available) air humidity between exhaust air and supply air. The HRC will be installed in casings or ducts. If fans are part of the test unit, the effect of the fan power on the measured values will be corrected. This document specifies procedures and input criteria required for tests to determine the performance of a HRC at one or several test conditions, each of them with continuous and stationary air flows, air temperatures and humidities at both inlet sides. Three different test types are covered: – Test type A, Laboratory testing of HRC installed in test casings (A1) or a HRC sections (A2); – Test type B, Laboratory testing of HRC installed in non-residential ventilation units in design configuration; – Test type C, on-site (field) testing of HRC in non-residential ventilation units (C1) or a HRC sections (C2) in operation configuration. This document is applicable to recuperators, regenerators, and HRC with intermediary heat transfer medium. This document prescribes test methods for determining: 1) the temperature and humidity efficiency, 2) the pressure drop of exhaust air and supply air sides, 3) possible internal leakages; exhaust air transfer ratio (EATR) and outdoor air correction factor (OACF), 4) external leakages and 5) auxiliary energy used for the operation of the HRC. HRC using heat pumps are not covered by this document.


Edition : 22
File Size : 1 file , 6.8 MB
Number of Pages : 88
Product Code(s) : DS-081, DS-081
Published : 04/04/2022

History

DANSK DSF/PREN 308
Published Date:
Heat exchangers – Test procedures for establishing performance of air to air and flue gases heat recovery devices
20.70 €
DANSK DSF/FPREN 308
Published Date:
Heat exchangers – Test procedures for establishing performance of air to air heat recovery components
20.70 €
DANSK DS/EN 308
Published Date: 04/04/2022
Heat exchangers – Test procedures for establishing performance of air to air heat recovery components
35.70 €
DANSK DS/EN 308
Published Date: 03/12/1997
Heat exchangers – Test procedures for establishing performance of air to air and flue gases heat recovery devices
13.20 €

Related products

DANSK DSF/FPREN 12697-21
Published Date:
Bituminous mixtures – Test methods – Part 21: Indentation using plate specimens
8.70 €
DANSK DS/EN 50553
Published Date: 03/26/2012
Railway applications - Requirements for running capability in case of fire on board of rolling stock
43.50 €
DANSK DS/CEN/TS 17394-4
Published Date: 01/18/2021
Textiles and textile products – Part 4: Safety of children's clothing – Security of attachment of components except buttons and metal mechanically applied press fasteners – Test method
13.20 €
DANSK DS/ISO 48
Published Date: 09/01/2016
Rubber, vulcanized or thermoplastic – Determination of hardness (hardness between 10 IRHD and 100 IRHD)
24.90 €

Best-Selling Products