DANSK DSF/FPREN 308 PDF

DANSK DSF/FPREN 308 PDF

Name:
DANSK DSF/FPREN 308 PDF

Published Date:

Status:
[ Draft-Obsolete ]

Description:

Heat exchangers – Test procedures for establishing performance of air to air heat recovery components

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$20.7
Need Help?
DRAFT * W/D S/S BY DS/EN 308

This document specifies methods to be used for testing of air-to-air heat recovery components (HRC). The main purpose of the HRC is to exchange heat between exhaust air and supply air in order to save energy, which results in – preheat or heat, and/or – precool or cool supply air in ventilation systems or air conditioning systems. Optionally HRC can exchange air humidity between exhaust and supply air. The HRC contains the heat exchangers and all necessary features and auxiliary devices for the exchange of sensible heat and (if available) air humidity between exhaust air and supply air. The HRC will be installed in casings or ducts. If fans are part of the test unit, the effect of the fan power on the measured values will be corrected. This document specifies procedures and input criteria required for tests to determine the performance of a HRC at one or several test conditions, each of them with continuous and stationary air flows, air temperatures and humidities at both inlet sides. Three different test types are covered: – Test type A, Laboratory testing of HRC installed in test casings (A1) or a HRC sections (A2); – Test type B, Laboratory testing of HRC installed in non-residential ventilation units in design configuration; – Test type C, On-site (field) testing of HRC in non-residential ventilation units (C1) or a HRC sections (C2) in operation configuration. This document is applicable to recuperators, regenerators, and HRC with intermediary heat transfer medium. This document prescribes test methods for determining: 1) the temperature and humidity efficiency, 2) the pressure drop of exhaust air and supply air sides, 3) possible internal leakages; exhaust air transfer ratio (EATR) and outdoor air correction factor (OACF), 4) external leakages and 5) auxiliary energy used for the operation of the HRC. HRC using heat pumps are not covered by this document.


Edition : 21
File Size : 1 file , 6.2 MB
Number of Pages : 87
Product Code(s) : DSF-061, DSF-061

History

DANSK DSF/PREN 308
Published Date:
Heat exchangers – Test procedures for establishing performance of air to air and flue gases heat recovery devices
$20.7
DANSK DSF/FPREN 308
Published Date:
Heat exchangers – Test procedures for establishing performance of air to air heat recovery components
$20.7
DANSK DS/EN 308
Published Date: 04/04/2022
Heat exchangers – Test procedures for establishing performance of air to air heat recovery components
$35.7
DANSK DS/EN 308
Published Date: 03/12/1997
Heat exchangers – Test procedures for establishing performance of air to air and flue gases heat recovery devices
$13.2

Related products

DANSK DS/EN 12023
Published Date: 11/29/1996
Self adhesive tapes - Measurement of water vapour transmission in a warm humid atmosphere
$11.4
DANSK DS/EN 14984
Published Date: 08/09/2016
Liming materials – Determination of product effect on soil pH – Soil incubation method
$22.5
DANSK DS/ISO/IEC 17960
Published Date: 11/13/2015
Information technology - Programming languages, their environments and system software interfaces - Code signing for source code
$14.7
DANSK DSF/PREN 63181-2
Published Date:
LCD multi-screen display terminals – Part 2: Measuring methods
$8.7

Best-Selling Products

CPA VCSDO
Published Date: 01/01/2009
Voluntary Compendium of Standards for Decorative Overlays
NPA A135.5-2004
Published Date: 03/11/2004
Prefinished Hardboard Paneling
$14.7
NPA A208.1-2009
Published Date: 2009
Particleboard
NPA A208.2-2009
Published Date: 2009
Medium Density Fiberboard (MDF) for Interior Applications