DANSK DS/EN ISO 5167-5 PDF

DANSK DS/EN ISO 5167-5 PDF

Name:
DANSK DS/EN ISO 5167-5 PDF

Published Date:
11/09/2022

Status:
[ Active ]

Description:

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full – Part 5: Cone meters (ISO 5167-5:2022)

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$19.2
Need Help?
SAME AS ISO 5167-5

This document specifies the geometry and method of use (installation and operating conditions) of cone meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. As the uncertainty of an uncalibrated cone meter might be too high for a particular application, it might be deemed essential to calibrate the flow meter in accordance with Clause 7. This document also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167‑1. This document is applicable only to cone meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated cone meters can only be used within specified limits of pipe size, roughness, β, and Reynolds number, Re. This document is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated cone meters in pipes sized less than 50 mm or more than 500 mm, or where the pipe Reynolds numbers are below 8 × 104 or greater than 1,2 × 107. A cone meter is a primary device which consists of a cone-shaped restriction held concentrically in the centre of the pipe with the nose of the cone upstream. The design of cone meter defined in this document has one or more upstream pressure tappings in the wall, and a downstream pressure tapping positioned in the back face of the cone with the connection to a differential pressure transmitter being a hole through the cone to the support bar, and then up through the support bar. Alternative designs of cone meters are available; however, at the time of writing, there is insufficient data to fully characterize these devices, and therefore, these meters shall be calibrated in accordance with Clause 7.


Edition : 22#
File Size : 1 file , 1.5 MB
Number of Pages : 28
Product Code(s) : DS-026, DS-026
Published : 11/09/2022

History

DANSK DSF/PREN ISO 5167-5
Published Date:
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full – Part 5: Cone meters (ISO/DIS 5167-5:2021)
$12
DANSK DS/EN ISO 5167-5
Published Date: 11/09/2022
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full – Part 5: Cone meters (ISO 5167-5:2022)
$19.2
DANSK DS/EN ISO 5167-5
Published Date: 04/07/2016
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full – Part 5: Cone meters
$19.2

Related products

DANSK DS/EN 13035-2
Published Date: 04/02/2008
Machines and plants for the manufacture, treatment and processing of flat glass – Safety requirements – Part 2: Storage, handling and transportation equipment outside the factory
$19.2
DANSK DS/EN 14323
Published Date: 11/29/2021
Wood-based panels – Melamine faced boards for interior uses – Test methods
$19.2
DANSK DS/EN IEC 60384-21
Published Date: 03/25/2019
Fixed capacitors for use in electronic equipment – Part 21: Sectional specification – Fixed surface mount multilayer capacitors of ceramic dielectric, Class 1
$27
DANSK DS/EN ISO 16148
Published Date: 05/17/2016
Gas cylinders – Refillable seamless steel gas cylinders and tubes – Acoustic emission examination (AT) and follow-up ultrasonic examination (UT) for periodic inspection and testing
$23.4

Best-Selling Products

Structural Analysis
Published Date: 03/01/1995