DANSK DS/EN ISO 5167-5 PDF

DANSK DS/EN ISO 5167-5 PDF

Name:
DANSK DS/EN ISO 5167-5 PDF

Published Date:
04/07/2016

Status:
[ Revised ]

Description:

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full – Part 5: Cone meters

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$19.2
Need Help?

This part of ISO 5167 specifies the geometry and method of use (installation and operating conditions) of cone meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. As the uncertainty of an uncalibrated cone meter might be too large for a particular application, it might be deemed essential to calibrate the flow meter in accordance with Clause 7. This part of ISO 5167 also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167-1. This part of ISO 5167 is applicable only to cone meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated cone meters can only be used within specified limits of pipe size, roughness, β, and Reynolds number. This part of ISO 5167 is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated cone meters in pipes sized less than 50 mm or more than 500 mm, or where the pipe Reynolds numbers are below 8 × 104 or greater than 1,2 × 107.


Edition : 16
File Size : 1 file , 1.3 MB
Number of Pages : 28
Product Code(s) : DS-026, DS-026
Published : 04/07/2016

History

DANSK DSF/PREN ISO 5167-5
Published Date:
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full – Part 5: Cone meters (ISO/DIS 5167-5:2021)
$12
DANSK DS/EN ISO 5167-5
Published Date: 11/09/2022
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full – Part 5: Cone meters (ISO 5167-5:2022)
$19.2
DANSK DS/EN ISO 5167-5
Published Date: 04/07/2016
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full – Part 5: Cone meters
$19.2

Related products

DANSK DSF/EN 14067-4/PRA1
Published Date:
Railway applications – Aerodynamics – Part 4: Requirements and test procedures for aerodynamics on open track
$4.2
DANSK DS/EN 61753-088-2
Published Date: 07/05/2013
Fibre optic interconnecting devices and passive components -Performance standard - Part 088-2: Non-connectorized single-mode fibre optic LAN WDM devices with channel spacing of 800 GHz for category C - Controlled environments
$22.5
DANSK DS/EN 61189-1
Published Date: 01/16/1998
Test methods for electrical materials, interconnection structures and assemblies - Part 1: General test methods and methodology
$27
DANSK DS/ISO/IEC 9314-20
Published Date: 11/04/2022
Information technology – Fibre Distributed Data Interface (FDDI) – Part 20: Abstract test suite for FDDI physical medium dependent conformance testing
$30

Best-Selling Products

ISEA 101-1996 (R2008)
Published Date: 01/06/1997
Limited-Use and Disposable Coveralls - Size and Labeling Requirements
$3
ISEA 101-2014
Published Date: 07/08/2014
American National Standard for Limited-Use and Disposable Coveralls -- Size and Labeling Requirements
$3
ISEA 102-1990 (R2009)
Published Date: 05/25/1990
American National Standard for Gas Detector Tube Units - Short Term Type for Toxic Gases and Vapors in Working Environments
$3
ISEA 103-2010 Erratum (2011)
Published Date: 09/07/2011
Erratum to American National Standard for Classification and Performance Requirements for Chemical Protective Clothing
Free Download
ISEA 103-2010
Published Date: 09/29/2010
American National Standard for Classification and Performance Requirements for Chemical Protective Clothing
$15.9
ISEA 104-1998 (R2009)
Published Date: 07/13/1998
Air Sampling Devices - Diffusive Type for Toxic Gases and Vapors in Working Environments
$3