DANSK DS/ISO 11140-6 PDF

DANSK DS/ISO 11140-6 PDF

Name:
DANSK DS/ISO 11140-6 PDF

Published Date:
12/06/2022

Status:
[ Active ]

Description:

Sterilization of health care products – Chemical indicators – Part 6: Type 2 indicators and process challenge devices for use in performance testing of small steam sterilizers

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$30
Need Help?

This document specifies the performance requirements and test methods for hollow devices and porous devices as well as the chemical indicators and biological indicators that are utilized within these devices for testing a specific steam penetration performance of type B cycles and some type S cycles of small steam sterilizers according to EN 13060. NOTE      The hollow and porous devices described in this document are not intended for use as surrogate devices for hollow and porous medical devices used in health care facilities. a)    Chemical indicators used with a porous device specified in this document are designed to demonstrate the adequacy of steam penetration into a porous device in small steam sterilizers (see EN 13060). This document specifies the requirements for: –    a reference porous device (RPD) as a reference device by which alternative porous indicator systems (APISs) can be shown to be equivalent in performance according to this document, i.e. a textile test pack in which steam penetration is judged by thermometric means; –    an alternative porous chemical indicator system equivalent in performance to the RPD, i.e. an APIS, usually commercially manufactured, of any design. b)    Chemical indicators used with a hollow load device specified in this document are designed to demonstrate the adequacy of steam penetration into a narrow lumen (previously known as hollow load A) in small steam sterilizers (see EN 13060). This document specifies the requirements for: –    a reference hollow device (RHD) used as a reference device in this document, i.e. a lumened device with attached capsule in which steam penetration is judged by inactivation or survival of a specified biological indicator; –    an alternative hollow device: –    employing the same specific test load as defined for the RHD and a chemical indicator designed specifically for use in the reference hollow test load, i.e. a lumened device with an attached capsule in which steam penetration is judged by visual examination of a chemical indicator; –    equivalent in performance to the RHD, i.e. an alternative hollow device, usually commercially manufactured, of any design.


Edition : 22#
File Size : 1 file , 2 MB
Number of Pages : 50
Product Code(s) : DS-041, DS-041
Published : 12/06/2022

History

DANSK DSF/ISO/DIS 11140-6
Published Date:
Sterilization of health care products – Chemical indicators – Part 6: Type 2 indicators and process challenge devices for use in performance testing of small steam sterilizers
$16.2
DANSK DS/ISO 11140-6
Published Date: 12/06/2022
Sterilization of health care products – Chemical indicators – Part 6: Type 2 indicators and process challenge devices for use in performance testing of small steam sterilizers
$30

Related products

DANSK DSF/PREN ISO 3037
Published Date:
Corrugated fibreboard – Determination of edgewise crush resistance (non-waxed edge method) (ISO/DIS 3037:2022)
$8.7
DANSK DS/IEC TS 62600-301
Published Date: 09/17/2019
Marine energy – Wave, tidal and other water current converters – Part 301: River energy resource assessment
$30
DANSK DS/EN 61386-21
Published Date: 03/26/2004
Conduit systems for cable management – Part 21: Particular requirements – Rigid conduit systems
$26.1
DANSK DS/EN ISO 21904-1
Published Date: 03/16/2020
Health and safety in welding and allied processes – Equipment for capture and separation of welding fume – Part 1: General requirements (ISO 21904-1:2020)
$23.4

Best-Selling Products

Knowledge Management Fieldbook, The
Published Date: 09/15/1999
$9