DANSK DS/ISO 16063-34 PDF

DANSK DS/ISO 16063-34 PDF

Name:
DANSK DS/ISO 16063-34 PDF

Published Date:
01/02/2020

Status:
[ Active ]

Description:

Methods for the calibration of vibration and shock transducers – Part 34: Testing of sensitivity at fixed temperatures

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$21.3
Need Help?

This document details specifications for the instrumentation and methods to be used for testing fixed temperature sensitivity of vibration transducers. It applies to rectilinear velocity and acceleration transducers. The methods specified use both a comparison to a reference transducer and an absolute measurement by laser interferometer. This document is applicable for a frequency range from 10 Hz to 3 kHz (method-dependent), a dynamic range from 1 m/s2 to 100 m/s2 (frequency-dependent) and a temperature range from ?190 �C to 800 �C (method-dependent). Although it is possible to achieve these ranges among all the described systems, generally each has limitations within them. Method 1 (using a laser interferometer) is applicable to magnitude of sensitivity and phase calibration in the frequency range 10 Hz to 3 kHz at fixed temperatures (see Clause 7). Method 2 (using a reference transducer inside a chamber whose temperature limit is ?70 �C to 500 �C) can be used for magnitude of sensitivity and phase calibration in the frequency range 10 Hz to 1 kHz at fixed temperatures (see Clause 8). Method 3 (using a reference transducer outside the chamber) can only be used for the determination of the temperature response of complex sensitivity over a certain temperature range (see Clause 9). NOTE – Method 1 and Method 2 can provide the deviation of complex sensitivity over a certain temperature range if the calibration is also done at the reference temperature (room temperature 23 �C � 5 �C). To ensure the consistency of the use and test condition, the transducer, its cable and the conditioning amplifier are intended to be considered as a single unit and tested together.


Edition : 20
File Size : 1 file , 2.2 MB
Number of Pages : 26
Product Code(s) : DS-026, DS-026
Published : 01/02/2020

History

DANSK DSF/ISO/FDIS 16063-34
Published Date:
Methods for the calibration of vibration and shock transducers -- Part 34: Testing of sensitivity at fixed temperatures
$13.5
DANSK DS/ISO 16063-34
Published Date: 01/02/2020
Methods for the calibration of vibration and shock transducers – Part 34: Testing of sensitivity at fixed temperatures
$21.3

Related products

DANSK DSF/ISO/FDIS 18759
Published Date:
Document management -- Trusted storage sub-system (TSS) functional and technical requirements
$13.5
DANSK DS/IEC 61196-1-316
Published Date: 04/25/2006
Coaxial communication cables - Part 1-316: Mechanical test methods - Test of maximum pulling force of cable
$12.6
DANSK DSF/EN 60335-2-6/FPRAA
Published Date:
Household and similar electrical appliances – Safety – Part 2-6: Particular requirements for stationary cooking ranges, hobs, ovens and similar appliances
$4.2

Best-Selling Products