DANSK DSF/ISO/FDIS 16063-34 PDF

DANSK DSF/ISO/FDIS 16063-34 PDF

Name:
DANSK DSF/ISO/FDIS 16063-34 PDF

Published Date:

Status:
[ Draft ]

Description:

Methods for the calibration of vibration and shock transducers -- Part 34: Testing of sensitivity at fixed temperatures

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$13.5
Need Help?
DRAFT

This document details specifications for the instrumentation and methods to be used for testing fixed temperature sensitivity of vibration transducers. It applies to rectilinear velocity and acceleration transducers. The methods specified use both comparison to a reference transducer, and absolute measurement by laser interferometer. This document is applicable for a frequency range from 10 Hz to 3 kHz (method-dependent), dynamic range from 1 m/s2 to 100 m/s2 (frequency-dependent) and temperature range from –190 °C to 800 °C (method-dependent). Although among all the described systems it is possible to achieve these ranges, generally each has limitations permitting their testing ranges. The methods and procedures described allow the determination of the complex sensitivity or temperature response of complex sensitivity of a transducer to sinusoidal vibration in the temperature chamber. Method 1 (using a laser interferometer) is applicable to magnitude of sensitivity and phase calibration in the frequency range 10 Hz to 3 kHz at fixed temperatures (see Clause 5). Method 2 (using a reference transducer inside a chamber whose temperature limit is –70 °C to 500 °C) can be used for magnitude of sensitivity and phase calibration in the frequency range 10 Hz to 1 kHz at fixed temperatures (see Clause 6). Method 3 (using a reference transducer outside the chamber) can only be used for the determination of the temperature response of complex sensitivity over a certain temperature range (see Clause 7). NOTE – Method 1 and Method 2 can provide the deviation of complex sensitivity over a certain temperature range if the calibration is also done at reference temperature (about 20 °C). In order to ensure the consistency of the use and test condition, the transducer, its cable and the conditioning amplifier should preferably be considered as a single unit and tested together.


Edition : 19
File Size : 1 file , 1.3 MB
Number of Pages : 25
Product Code(s) : DSF-021, DSF-021

History

DANSK DSF/ISO/FDIS 16063-34
Published Date:
Methods for the calibration of vibration and shock transducers -- Part 34: Testing of sensitivity at fixed temperatures
$13.5
DANSK DS/ISO 16063-34
Published Date: 01/02/2020
Methods for the calibration of vibration and shock transducers – Part 34: Testing of sensitivity at fixed temperatures
$21.3

Related products

DANSK DS/EN 1001-2
Published Date: 09/30/2005
Durability of wood and wood based products - Terminology - Part 2: Vocabulary
$35.7
DANSK DSF/IEC 60826 ED. 4.0
Published Date:
IEC 60826/Ed4: Overhead transmission lines – design criteria
$23.1
DANSK DS/CEN ISO/TR 9241-331
Published Date: 09/17/2013
Ergonomics of human-system interaction - Part 331: Optical characteristics of autostereoscopic displays
$35.7
DANSK DS/EN IEC 62769-7
Published Date: 05/25/2023
Field Device Integration (FDI®) – Part 7: Communication Devices
$33

Best-Selling Products