DANSK DSF/PREN IEC 62056-3-1 PDF

DANSK DSF/PREN IEC 62056-3-1 PDF

Name:
DANSK DSF/PREN IEC 62056-3-1 PDF

Published Date:

Status:
[ Draft-Obsolete ]

Description:

Electricity metering data exchange – The DLMS/COSEM suite – Part 3-1: Use of local area networks on twisted pair with carrier signalling

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
dansk-dsf-pren-iec-62056-3-1_2669189

Choose Document Language:
20.70 €
Need Help?
DRAFT * W/D S/S BY DS/EN IEC 62056-3-1

This part of IEC 62056 describes two sets of profiles: the first set of profiles allows a bidirectional communication between a client and a server. This set of profile is made of three profiles allowing local bus data exchange with stations either energized or not. For non energized stations, the bus supplies energy for data exchange.Three different profiles are supported: • base profile: this three-layer profile provides remote communication services; NOTE – This first profile has been published in IEC 61142:1993 and became known as the Euridis standard. • profile with DLMS: this profile allows using DLMS services as specified in IEC 61334-4- 41; NOTE – This second profile has been published in IEC 62056-31 Ed. 1.0:1999; • profile with DLMS/COSEM: this profile allows using the DLMS/COSEM Application layer and the COSEM object model as specified in IEC 62056-5-3 Ed. 1.0:– and in IEC 62056-6-2 Ed. 1.0:– respectively. The three profiles use the same physical layer and they are fully compatible, meaning that devices implementing any of these profiles can be operated on the same bus. The transmission medium is twisted pair using carrier signalling and it is known as the Euridis Bus. The second set of profiles allows unidirectional communication between a given Energy Metering device and a Customer Energy Management System. This second set is made up of three profiles. The clauses 4.2.1 to 8 included specify the bidirectional communication using twisted pair signalling and clauses 9 to 9.5 the unidirectional communication using twisted pair signalling.


Edition : 20
File Size : 1 file , 1.8 MB
Number of Pages : 118
Product Code(s) : DSF-061, DSF-061

History

DANSK DSF/PREN IEC 62056-3-1
Published Date:
Electricity metering data exchange – The DLMS/COSEM suite – Part 3-1: Use of local area networks on twisted pair with carrier signalling
20.70 €
DANSK DS/EN IEC 62056-3-1
Published Date: 08/30/2021
Electricity metering data exchange – The DLMS/COSEM suite – Part 3-1: Use of local area networks on twisted pair with carrier signalling
42.90 €

Related products

DANSK DS/EN 13207
Published Date: 03/05/2018
Plastics – Thermoplastic silage films and tubes for use in agriculture
18.00 €
DANSK DS/EN 12653 + A2
Published Date: 09/16/2009
Footwear, leather and imitation leather manufacturing machines – Nailing machines – Safety requirements
19.20 €
DANSK DS/ISO 16055
Published Date: 08/02/2021
Tobacco and tobacco products – Monitor test piece for smoking machine – Requirements and use
14.70 €
DANSK DSF/ISO/FDIS 22554
Published Date:
Ships and marine technology – Propeller shaft revolution indicators – Electric type and electronic type
9.60 €

Best-Selling Products

LIA Z136.1-2007
Published Date: 03/16/2007
Safe Use of Lasers
LIA Z136.1-2014
Published Date: 2013
Safe Use of Lasers
60.90 €
LIA Z136.1-2022
Published Date: 2022
Safe Use of Lasers
67.50 €
LIA Z136.2-2012
Published Date: 12/19/2012
Safe Use of Optical Fiber Communication Systems Utilizing Laser Diode and LED Sources
45.00 €
LIA Z136.3-2005
Published Date: 01/06/2005
Safe Use of Lasers in Health Care Facilities
LIA Z136.3-2011
Published Date: 12/05/2011
Safe Use of Lasers in Health Care Facilities
47.40 €