Mechanical structures for electrical and electronic equipment – Thermal management for cabinets in accordance with IEC 60297 and IEC 60917 Series – Part 6: Air recirculation and bypass of indoor cabinets

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$12
Need Help?
DRAFT * W/D NO S/S

This part of IEC 62610 which deals with thermal management for cabinets in accordance with IEC 60297 and IEC 60917 series, provides for compatible measurement methods of recirculation ratio and bypass ratio which are indicators for defining quality of airflow in the forced air cooling that can be commonly applied to indoor cabinets for mounting subrack and/or chassis-based equipment. NOTE 1 – Both recirculation and bypass represent leakage airflows, i.e. detrimental phenomena in terms of cooling efficiency; their measurement is obviously aimed at their mitigation. This document contains the following: a) the definition of recirculation and bypass flow rates in the cooling of the cabinet, b) the levels of the recirculation ratio RC, c) the definition of the formula for the recirculation ratio RCs of forced air cooling subrack and/or chassis-based equipment installed in the cabinet, d) the definition formula of recirculation ratio RCr and bypass rate BPr of the entire cabinet, e) the requirements of the measuring method of each temperature necessary for calculating the recirculation ratio RCs, RCr and bypass ratio BPr. NOTE 2 – This document includes the definition of measuring bypass ratio, but excludes the definition of levels of bypass ratio. The drawings used are not intended to indicate product design. They are only for explanatory indications for defining forced air cooling airflows. The recirculation and bypass measurement methods dealt with in this document are assumed to be applied to a cabinet installed indoors. The cooling air inlet is at the front or the bottom of the cabinet and the heated air is exhausted to the rear or the top. These methods are also applicable to a cabinet that is installed outdoors and has a cooling device such as a heat exchanger or an air conditioner on the front or the back (see Annex C). The recirculation ratio of a subrack or a cabinet is defined for each individual subrack or chassis-based equipment mounted in the cabinet or for the entire cabinet. The bypass ratio of a cabinet is defined for the entire cabinet.


Edition : 19
File Size : 1 file , 1.6 MB
Number of Pages : 28
Product Code(s) : DSF-021, DSF-021

History

DANSK DSF/PREN IEC 62610-6
Published Date:
Mechanical structures for electrical and electronic equipment – Thermal management for cabinets in accordance with IEC 60297 and IEC 60917 Series – Part 6: Air recirculation and bypass of indoor cabinets
$12
DANSK DS/EN IEC 62610-6
Published Date: 05/18/2020
Mechanical structures for electrical and electronic equipment – Thermal management for cabinets in accordance with IEC 60297 and IEC 60917 series – Part 6: Air recirculation and bypass of indoor cabinets
$22.5

Related products

DANSK DS/EN IEC 61754-35
Published Date: 06/08/2020
Fibre optic interconnecting devices and passive components – Fibre optic connector interfaces – Part 35: Type LSHE connector family for harsh environments
$19.2
DANSK DS/CWA 16926-3
Published Date: 01/12/2023
Extensions for Financial Services (XFS) interface specification Release 3.50 – Part 3: Printer and Scanning Device Class Interface – Programmer's Reference
$42.9
DANSK DS/ISO 20632
Published Date: 06/04/2008
Reaction-to-fire tests - Small room test for pipe insulation products or systems
$26.1
DANSK DS/EN 61800-7-302
Published Date: 04/06/2016
Adjustable speed electrical power drive systems - Part 7-302: Generic interface and use of profiles for power drive systems - Mapping of profile type 2 to network technologies
$23.4

Best-Selling Products

ASD-STAN prEN 2002-003
Published Date: 12/01/1975
Test methods for metallic materials - Part 3 : Load calibration of tensile testing machines
$2.616
ASD-STAN prEN 2002-006
Published Date: 01/31/2000
Metallic materials - Test methods - Part 6 : Bend testing
$25.179
ASD-STAN prEN 2002-017
Published Date: 05/31/1991
Test methods for metallic materials - Tube used under pressure - Part 17 : Integrity test
$2.616
ASD-STAN prEN 2002-018
Published Date: 05/31/1991
Test methods for metallic materials - Part 18 : Hydraulic distension test for tube
$5.232
ASD-STAN prEN 2002-020
Published Date: 02/29/1996
Test methods for metallic materials - Part 20: Eddy current testing of circular cross-section tubes
$22.563
ASD-STAN prEN 2002-021
Published Date: 01/31/2000
Metallic materials - Test methods - Part 21 : Radiographic testing of castings
$8.502