DANSK DSF/PREN IEC 62990-1/PRAA PDF

DANSK DSF/PREN IEC 62990-1/PRAA PDF

Name:
DANSK DSF/PREN IEC 62990-1/PRAA PDF

Published Date:

Status:
[ Draft-Obsolete ]

Description:

Workplace Atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.2
Need Help?
DRAFT * W/D S/S BY DS/EN IEC 62990-1

This part of IEC 62990 specifies general requirements for design, function and performance, and describes the test methods that apply to portable, transportable, and fixed equipment for the detection and concentration measurement of toxic gases and vapours in workplace atmospheres and other industrial and commercial applications. This document is applicable to continuously sensing equipment whose primary purpose is to provide an indication, alarm and/or other output function the purpose of which is to indicate the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate automatic or manual protective action(s). It is applicable to equipment in which the sensor generates an electrical signal when gas is present. This document applies to two types of equipment: • Type HM (Health Monitoring) ‘occupational exposure’ equipment: For occupational exposure measurement, the performance requirements are focused on uncertainty of measurement of gas concentrations in the region of Occupational Exposure Limit Values (OELV). The upper limit of measurement will be defined by the manufacturer in accordance with 4.2.1. • Type SM (Safety Monitoring) ‘general gas detection’ equipment: For general gas detection applications (e.g. safety warning, leak detection), the performance requirements are focused on alarm signalling. The upper limit of measurement will be defined by the manufacturer according to the intended use of the equipment. In general, the requirements for accuracy will be higher for Type HM equipment than for Type SM equipment. The same equipment may meet the requirements of both Type HM and Type SM. For equipment used for sensing the presence of multiple gases this document applies only to the detection of toxic gas or vapour. This document is not applicable to equipment: - with samplers and concentrators such as sorbents or paper tape having an irreversible indication; - used for the measurement of gases and vapours related to the ...


Edition : 22
File Size : 1 file , 860 KB
Number of Pages : 7
Product Code(s) : DSF-001, DSF-001

History

DANSK DSF/PREN IEC 62990-1/PRAA
Published Date:
Workplace Atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases
$4.2
DANSK DSF/PREN IEC 62990-1
Published Date:
Workplace Atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases
$4.2
DANSK DS/EN IEC 62990-1
Published Date: 10/26/2022
Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases
$33
DANSK DS/EN IEC 62990-1/A11
Published Date: 10/25/2022
Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases
$8.4

Related products

DANSK DS/ISO 1833-15
Published Date: 11/26/2019
Textiles – Quantitative chemical analysis – Part 15: Mixtures of jute with certain animal fibres (method by determining nitrogen content)
$12.6
DANSK DS/CEN/TR 16219
Published Date: 01/12/2012
Electronic Fee Collection - Value added services based on EFC on-board equipment
$35.7
DANSK DS/ISO/IEC 8613-8
Published Date: 11/28/1995
Information technology - Open Document Architecture (ODA) and Interchange Format: Geometric graphics content architectures
$33.6
DANSK DS/ISO 15152/AMD 2
Published Date: 03/16/2020
Tobacco – Determination of the content of total alkaloids as nicotine – Continuous-flow analysis method – Amendment 2
$4.8

Best-Selling Products