DNV DNVGL-RP-F110 PDF

DNV DNVGL-RP-F110 PDF

Name:
DNV DNVGL-RP-F110 PDF

Published Date:
08/01/2017

Status:
[ Revised ]

Description:

Global buckling of submarine pipelines due to high temperature/high pressure

Publisher:
DNV

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
dnv-dnvgl-rp-f110_2855076

Choose Document Language:
43.50 €
Need Help?

Scope and application

This recommended practice applies to structural design of rigid pipelines with a potential to buckle globally. This normally implies so called HP/HT pipelines but also moderately tempered pipelines may be of relevance depending on the global buckling resistance (e.g. very light pipelines). Hence, it does not include considerations with respect to temperature and pressure effects on materials, insulation, thermal conditions and flow assurance but gives procedures and criteria to global buckling only. Consequently, there are no limitations to pressure or temperature other than those caused by structural limitations from the material properties etc.

Global buckling is a load response and not a failure mode as such. Global buckling may, however, imply an ultimate failure mode such as:

— local buckling

— fracture

— fatigue.

This recommended practice covers global buckling ultimately limited by local buckling. The procedures provide also best estimates and upper bound strain values that may be used in a fracture assessment. For other failure modes reference is made to DNVGL-ST-F101.

Three global buckling scenarios of HT/HP pipelines are covered in this Recommended Practice:

1) Exposed pipelines on even seabed. Global buckling occurs in the horizontal plane. Post buckling configuration may be allowed.

2) Exposed pipelines on un-even seabed. Global deformation occurs first in the vertical plane (feed-in and uplift) and subsequently in the horizontal plane or when this is combined with scenario I, e.g. for curves on un-even seabed. Post buckling configuration may be allowed.

3) Buried/covered pipelines. Global buckling in the vertical plane, so called upheaval buckling. Only criteria for avoiding global buckling are given.

The trawl interference evaluation in this recommended practice is limited to lateral buckling only. Hence, trawling in free span is not covered by this recommended practice but by DNVGL-RP-F111.

With reference to trawling applicability see also [3.5.3]. For other design issues, reference is made to other codes, see [1.5].

The design procedures and criteria in this recommended practice are based on vast number of analyses. In spite of this very special combinations may give un-anticipated results and the designer shall evaluate all results critically.

The provided design procedures are considered being applicable in general. The basis for the development has been pipelines in the range from 10” to 42”.


Edition : 17
File Size : 1 file , 1.8 MB
Number of Pages : 91
Published : 08/01/2017

History

DNV DNV-RP-F110
Published Date: 09/01/2019
Global buckling of submarine pipelines
43.50 €
DNV DNVGL-RP-F110
Published Date: 09/01/2019
Global buckling of submarine pipelines
43.50 €
DNV DNVGL-RP-F110
Published Date: 09/01/2019
Global buckling of submarine pipelines
43.50 €
DNV DNVGL-RP-F110
Published Date: 04/01/2018
Global buckling of submarine pipelines
43.50 €
DNV DNVGL-RP-F110
Published Date: 08/01/2017
Global buckling of submarine pipelines due to high temperature/high pressure
43.50 €

Related products

DNV DNV-RU-SHIPS PART 5 CHAPTER 3
Published Date: 07/01/2016
NEWBUILDINGS SPECIAL SERVICE AND TYPE - ADDITIONAL CLASS - Oil carriers
17.10 €
DNV DNV-CG-0129
Published Date: 10/01/2021
Fatigue assessment of ship structures
17.10 €
DNV DNV-RU-SHIPS PART 0 CHAPTER 1
Published Date: 07/01/2016
INTRODUCTION User information and current rule chapters
17.10 €
DNV DNV-SI-0166
Published Date: 07/01/2021
Verification for compliance with Norwegian shelf regulations
17.10 €

Best-Selling Products

CAN/CSA-CEI/IEC 1000-1-1-97 (R2023)
Published Date: 01/18/2000
Electromagnetic Compatibility (EMC) - Part 1: General - Section 1: Application and Interpretation of Fundamental Definitions and Terms (Adopted CEI/IEC 1000-1-1:1992)
37.80 €
CAN/CSA-CEI/IEC 1000-2-1-97 (R2023)
Published Date: 01/18/2000
Electromagnetic Compatibility (EMC) - Part 2: Environment - Section 1: Description of the Environment - Electromagnetic Environment for Low-Frequency Conducted Disturbances and Signalling in Public Power Supply Systems (Adopted CEI/IEC 1000- 2-1:1990) / Compatibilite electromagnetique (CEM) - Partie
36.30 €
CAN/CSA-CEI/IEC 1160-96 (R2001)
Published Date: 05/03/2000
Formal Design Review (Adopted CEI/IEC 1160:1992) / Revue de conception formalisee (norme CEI/IEC 1160:1992 adoptee)
31.50 €
CAN/CSA-CEI/IEC 1258-98 (R2002)
Published Date: 02/25/2000
Guidelines for the Development and Use of Medical Electrical Equipment Educational Materials (Adopted CEI/IEC 1258:1994, first edition) / Guide pour le developpement et l'utilisation des supports educatifs relatifs aux appareils electromedicaux (norme CEI/IEC 1258:1994 adoptee, premiere edition) **
CAN/CSA-CEI/IEC 1288-1-98 (R2012)
Published Date: 02/16/2000
Cardiac Defibrillators - Cardiac Defibrillators-Monitors - Part 1: Operation (Adopted CEI/IEC 1288-1:1993, first edition) / Defibrillateurs cardiaques - Moniteurs-defibrillateurs cardiaques - Partie 1: Fonctionnement (norme CEI/IEC 1288-1:1993 adoptee, premiere edition)
CAN/CSA-CEI/IEC 1288-2-98 (R2012)
Published Date: 02/16/2000
Cardiac Defibrillators - Cardiac Defibrillators-Monitors - Part 2: Maintenance (Adopted CEI/IEC 1288-2:1993, first edition) / Defibrillateurs cardiaques - Moniteurs-defibrillateurs cardiaques - Partie 2: Maintenance (norme CEI/IEC 1288-2:1993 adoptee, premiere edition)