ASSE (Plumbing) 1048-2021e1 PDF

ASSE (Plumbing) 1048-2021e1 PDF

Name:
ASSE (Plumbing) 1048-2021e1 PDF

Published Date:
06/01/2021

Status:
Active

Description:

Performance Requirements for Double Check Detector Backflow Prevention Assemblies

Publisher:
American Society of Sanitary Engineering

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$13.5
Need Help?

The purpose of a Double Check Detector Backflow Prevention Assemblies is to keep polluted water from flowing into a potable water distribution system when some abnormality in the system causes the pressure to be temporarily higher in the polluted part of the system than in the potable water supply piping. These assemblies are also designed to detect low rates of flow up to 2 gpm (0.13 L/s) caused by leakage or unauthorized use.

 

This standard applies to 2 types of assemblies identified as:

a) Double Check Detector Assembly (DCDA).

b) Double Check Detector Assembly Type II (DCDA-II).

 

The DCDA and DCDA-II assemblies consist of 2 independently acting check valves, internally force loaded to a normally closed position. These assemblies are designed to operate under continuous pressure conditions. The assembly shall include 2 properly located, tightly closing shut-off valves per Section 1.3.2.6; and properly located test cocks per Section 1.3.2.4. The assemblies also include a bypass line which provides a visual or audible indication of system leakage or unauthorized use of water.


ANSI : ANSI Approved
File Size : 1 file , 1.3 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 32
Published : 06/01/2021

History

ASSE (Plumbing) 1048-2021e1
Published Date: 06/01/2021
Performance Requirements for Double Check Detector Backflow Prevention Assemblies
$13.5
ASSE (Plumbing) 1048-2011
Published Date: 08/17/2011
Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies
$13.5
ASSE (Plumbing) 1048-2009
Published Date: 07/01/2009
Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies
$13.5
ASSE (Plumbing) 1048-2005
Published Date: 01/01/2005
Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies

Related products

ASSE (Plumbing) 1011-2023
Published Date: 04/01/2023
Performance Requirements for Hose Connection Vacuum Breakers
$13.5
ASSE (Plumbing) LEC 2006-2019
Published Date: 2019
Listing Evaluation Criteria for Backflow Preventer and Automatic Boiler or Chiller Filling Device with Pressure Regulating Management
$13.5

Best-Selling Products