IEC 60287-2-1 Ed. 3.0 en:2023 PDF

IEC 60287-2-1 Ed. 3.0 en:2023 PDF

Name:
IEC 60287-2-1 Ed. 3.0 en:2023 PDF

Published Date:
05/01/2023

Status:
Active

Description:

Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of the thermal resistance

Publisher:
International Electrotechnical Commission

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$98.7
Need Help?

This part of IEC 60287 is solely applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, in troughs or in steel pipes, both with and without partial drying-out of the soil, as well as cables in air. The term "steady state" is intended to mean a continuous constant current (100 % load factor) just sufficient to produce asymptotically the maximum conductor temperature, the surrounding ambient conditions being assumed constant.

This document provides formulae for thermal resistance.

The formulae given are essentially literal and designedly leave open the selection of certain important parameters. These can be divided into three groups:
– parameters related to construction of a cable (for example, thermal resistivity of insulating material) for which representative values have been selected based on published work;
– parameters related to the surrounding conditions which can vary widely, the selection of which depends on the country in which the cables are used or will be used;
– parameters which result from an agreement between manufacturer and user and which involve a margin for security of service (for example, maximum conductor temperature).

Equations given in this document for calculating the external thermal resistance of a cable buried directly in the ground or in a buried duct are for a limited number of installation conditions. Where analytical methods are not available for calculation of external thermal resistance finite element methods can be used. Guidance on the use of finite element methods for calculating cable current ratings is given in IEC TR 62095.


Edition : 3.0
File Size : 1 file , 3.2 MB
ISBN(s) : 9782832269817
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 52
Published : 05/01/2023

History

IEC 60287-2-1 Ed. 3.0 en:2023
Published Date: 05/01/2023
Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of the thermal resistance
$98.7
IEC 60287-2-1 Ed. 1.2 b:2006
Published Date: 05/18/2006
Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance CONSOLIDATED EDITION
$94.5
IEC 60287-2-1 Ed. 1.1 b:2001
Published Date: 11/22/2001
Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance CONSOLIDATED EDITION
$32.4

Related products

IEC 60092-373 Ed. 1.0 b:1977
Published Date: 01/01/1977
Electrical installations in ships. Shipboard telecommunication cables and radio-frequency cables. Shipboard flexible coaxial cables
$5.4
IEC 60050-461 Ed. 2.0 b:2008
Published Date: 06/11/2008
International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
$125.1
IEC 60986 Ed. 2.1 b:2008
Published Date: 11/13/2008
Short-circuit temperature limits of electric cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) CONSOLIDATED EDITION
$24.6
IEC 62930 Ed. 1.0 en:2017
Published Date: 12/13/2017
Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC
$70.2

Best-Selling Products