ISA 60079-26 PDF

ISA 60079-26 PDF

Name:
ISA 60079-26 PDF

Published Date:
01/01/2008

Status:
[ Revised ]

Description:

Electrical Apparatus for Use in Class I, Zone 0 Hazardous (Classified) Locations

Publisher:
The International Society of Automation

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?

This standard specifies the particular requirements for construction, test and marking for electrical apparatus of Group II intended for use in Class I, Zone 0 as defined in the National Electrical Code, ANSI/NFPA 70.

This electrical apparatus, within the operational parameters specified by the manufacturer, ensures a very high level of protection that includes rare faults related to the apparatus or two faults occurring independently of each other.

NOTE 1 A malfunction may result from a failure of the component parts of the electrical apparatus or from anticipated externally applied influences. Two independent malfunctions which may occur more frequently and which, separately, would not create an ignition hazard but which, in combination, could create a potential ignition hazard, should be regarded as occurring together to form a rare fault.

This electrical apparatus is intended for use in Class I, Zone 0 hazardous areas, in which explosive gas atmospheres caused by mixtures of air and gases, vapours or mists under normal atmospheric conditions are present continuously, for long periods or frequently.

This standard also applies to apparatus mounted across the boundary between Class I, Zone 0 and Class I, Zone 1.

EXAMPLE: In the wall of a storage vessel.

This standard also applies to apparatus installed outside Class I, Zone 0, but electrically connected to apparatus inside Class I, Zone 0 (associated apparatus).

This standard supplements the general requirements in ANSI/ISA-60079-0

NOTE 2 In designing apparatus for operation in explosive gas atmospheres under conditions other than the atmospheric conditions given in IEC 60079-0, this standard may be used as a guide. However, additional testing is recommended related specifically to the intended conditions of use. This is particularly important when the types of protection ‘Flameproof enclosure' (ANSI/ISA-60079-1) and ‘Intrinsic safety' (ANSI/ISA- 60079-11) are applied.

NOTE 3 The classification of hazardous areas in zones is defined in the National Electrical Code.

NOTE 4 There may be other non-electrical sources of ignition (for example ultrasonic, optical or ionizing radiation) that are not addressed by this standard; these should also be taken into consideration (see, for example, EN 1127-1).


ANSI : ANSI Approved
Edition : 08
File Size : 1 file , 98 KB
Number of Pages : 28
Published : 01/01/2008

History


Related products

ISA 77.43.01
Published Date: 12/22/2014
Fossil Fuel Power Plant Unit/ Plant Demand Development
$26.1
ISA 75.13.01
Published Date: 12/02/2013
Method of Evaluating the Performance of Positioners with Analog Input Signals and Pneumatic Output
$26.1
ISA 61241-2
Published Date: 01/01/2006
Electrical Apparatus for Use in Zone 21 and Zone 22 Hazardous (Classified) Locations − Protection by Pressurization “pD”
$56.7

Best-Selling Products

ACC RC14001:2008
Published Date: 02/29/2008
Responsible Care 14001 Technical Specification
ACC RC14001:2015
Published Date: 09/25/2015
Responsible Care 14001 Technical Specification
ACC RC14001:2023
Published Date: 02/15/2023
Responsible Care 14001 Technical Specification