Description:

Wires, Cords, and Cables, Electrical Part: 25 : Cables, Electrical Limited Fire Hazard, up to Conductor Size 10 mm2 Cross Sectional Area

Publisher:
British Defence Standards

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The cables shall be suitable for use on electric power and communications circuits with a potential not exceeding 600V AC RMS, 800V DC between cores, or between cores and the surrounding structure, or between cores and earthed screen(s) included in the cable, at frequencies up to 400Hz. The maximum cable conductor size is 10 mm2 cross-sectional area.

The cables detailed herein use insulated cores complying with Def. Stan 61-12 (Part 18) type and the sheathing material complies with Def. Stan 61-12 (Part 31). They present a limited fire hazard cable, producing limited levels of noxious fumes, smoke and corrosive products when burnt.

The materials used for cable constructions will give a service life exceeding 40,000 hours at a continuous conductor temperature of 85°C.

Users should be aware that only cables with Standard, Type 1 – pliable type cores are now included in his standard. The Type 2 - less pliable cored cable which were listed in previous issues have been removed.

Users should check that these cables are compatible with the terminations and connectors with which they are to be terminated, with particular reference to cable connector sizes and insulation diameters.

All requirements and tests specified in this Standard are applicable.


Edition : I6
File Size : 1 file , 1.7 MB
Number of Pages : 63
Published : 01/14/2022

History

MODUK DEF STAN 61-012: PART 25
Published Date: 01/14/2022
Wires, Cords, and Cables, Electrical Part: 25 : Cables, Electrical Limited Fire Hazard, up to Conductor Size 10 mm2 Cross Sectional Area
$4.8
MODUK DEF STAN 61-12: PART 25
Published Date: 06/18/2010
Wires, Cords and Cables Electrical Part 25: Wires and Cables Electrical Limited Fire Hazard, up to Conductor Size 10mm2 Cross Sectional Area
MODUK DEF STAN 61-12: PART 25
Published Date: 05/12/2006
Wires, Cords and Cables Electrical - Metric Units Part 25: Cables Electrical Limited Fire Hazard, up to Conductor Size 10 mm2 Cross Sectional Area
MODUK DEF STAN 61-12: PART 25
Published Date: 05/12/2006
Wires, Cords and Cables Electrical - Metric Units Part 25: Cables Electrical Limited Fire Hazard, up to Conductor Size 10 mm2 Cross Sectional Area

Related products


Best-Selling Products

SWRI APPLICATOR MAGAZINE
Published Date:
Applicator Magazine
$24.9
SWRI APPLYING LIQUID SEALANTS
Published Date:
Applying Liquid Sealants Program
$24.9
SWRI CLEAR WATER REPELLENT FOR MASONRY
Published Date:
CLEAR WATER REPELLENT FOR MASONRY
$0.3
SWRI CPWR SAFETY VIDEOS
Published Date:
CPWR Safety Videos
$39.6
SWRI SAFETY & HEALTH
Published Date:
Safety & Health Field Manual
$6.6
SWRI SEALANTS
Published Date:
Sealants: the Professionals' Guide
$24.9