MODUK DEF STAN 61-12: PART 25 PDF

MODUK DEF STAN 61-12: PART 25 PDF

Name:
MODUK DEF STAN 61-12: PART 25 PDF

Published Date:
06/18/2010

Status:
[ Revised ]

Description:

Wires, Cords and Cables Electrical Part 25: Wires and Cables Electrical Limited Fire Hazard, up to Conductor Size 10mm2 Cross Sectional Area

Publisher:
British Defence Standards

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?

The cables shall be suitable for use on electric power and communications circuits with a potential not exceeding 600V AC RMS, 800V DC between cores, or between cores and the surrounding structure, or between cores and earthed screen(s) included in the cable, at frequencies up to 400Hz. The maximum cable conductor size is 10 mm2 cross-sectional area.

The cables detailed herein use insulated cores complying with Tables 9 to 12 or Table 17 of Def Stan 61-12 (Part 18) type and the sheathing material complies with Def Stan 61-12 (Part 31). They present a limited fire hazard cable, producing limited levels of noxious fumes, smoke and corrosive products when burnt.

The materials used for cable constructions will give a service life exceeding 40,000 hours at a continuous conductor temperature of 85°C.

Users should be aware that only cables with Standard, Type 1 – pliable type cores are now included in this standard. The Type 2 - less pliable cored cable which were listed in previous issues have been removed.

Users should check that these cables are compatible with the terminations and connectors with which they are to be terminated, with particular reference to cable connector sizes and insulation diameters.

All requirements and tests specified in this Standard are applicable.


Edition : I5
Number of Pages : 58
Published : 06/18/2010

History

MODUK DEF STAN 61-012: PART 25
Published Date: 01/14/2022
Wires, Cords, and Cables, Electrical Part: 25 : Cables, Electrical Limited Fire Hazard, up to Conductor Size 10 mm2 Cross Sectional Area
$4.8
MODUK DEF STAN 61-12: PART 25
Published Date: 06/18/2010
Wires, Cords and Cables Electrical Part 25: Wires and Cables Electrical Limited Fire Hazard, up to Conductor Size 10mm2 Cross Sectional Area
MODUK DEF STAN 61-12: PART 25
Published Date: 05/12/2006
Wires, Cords and Cables Electrical - Metric Units Part 25: Cables Electrical Limited Fire Hazard, up to Conductor Size 10 mm2 Cross Sectional Area
MODUK DEF STAN 61-12: PART 25
Published Date: 05/12/2006
Wires, Cords and Cables Electrical - Metric Units Part 25: Cables Electrical Limited Fire Hazard, up to Conductor Size 10 mm2 Cross Sectional Area

Related products

MODUK DEF STAN 13-96: PART 3
Published Date: 09/11/2009
Lotting and Batching of Ammunition Part 3: Ammunition Lotted or Batched with its Governing Components
$1.2

Best-Selling Products

NS-EN ISO/ASTM 52900:2017
Published Date: 05/01/2017
Additive manufacturing - General principles - Terminology (ISO/ASTM 52900:2015)
NS-EN ISO/ASTM 52900:2021
Published Date: 12/16/2021
Additive manufacturing - General principles - Fundamentals and vocabulary (ISO/ASTM 52900:2021)
NS-EN ISO/ASTM 52901:2018
Published Date: 01/01/2019
Additive manufacturing - General principles - Requirements for purchased AM parts (ISO/ASTM 52901:2017)
NS-EN ISO/ASTM 52902:2019
Published Date: 12/01/2019
Additive manufacturing - Test artifacts - Geometric capability assessment of additive manufacturing systems (ISO/ASTM 52902:2019)
NS-EN ISO/ASTM 52903-1:2021
Published Date: 03/25/2021
Additive manufacturing - Material extrusion-based additive manufacturing of plastic materials - Part 1: Feedstock materials (ISO/ASTM 52903-1:2020)
NS-EN ISO/ASTM 52903-2:2020
Published Date: 11/16/2020
Additive manufacturing — Material extrusion based additive manufacturing of plastic materials — Part 2: Process equipment (ISO/ASTM 52903-2:2020)