MODUK DEF STAN 61-12: PART 9 PDF

MODUK DEF STAN 61-12: PART 9 PDF

Name:
MODUK DEF STAN 61-12: PART 9 PDF

Published Date:
11/30/2008

Status:
[ Beyond Review Date ]

Description:

Wires, Cords and Cables Electrical - Metric Units Part 9: Cables and Wires Electrical for Cables, Radio Frequency Including Limited Fire Hazard (LFH) Variants

Publisher:
British Defence Standards

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$14.1
Need Help?
CANC NO S/S

This Defence Standard specifies the requirements for Cables and Wires Electrical for Radio Frequency Including Limited Fire Hazard (LFH) Variants for use in equipment used by the MOD.

This part of the Standard lists by type (Table 1 to Table 4) cables to be used by the Ministry of Defence for new requirements and replacement purposes.

The requirements and tests for limited fire hazard sheathing material for cables radio frequency are specified in Defence Standard 61-12 (Part 31).

Cable sheaths manufactured to Defence Standard 61-12 (Part 31) present limited levels of noxious fumes, smoke and corrosive products when assessed by the methods of test specified therein.

Cables in Table 1 Groups 1 to 6 inclusive where those metric cables formerly specified in BS 2316.

Cables in Table 1 Groups 7 to 11 inclusive are low fire hazard variants which are suitable for use within the temperature range - 30°C to + 85°C. The upper temperature limit refers to the combination of ambient temperature and the temperature rise due to the continuous current flow in the cable conductors. In practice it can be assumed that the cables will be operating at their normal conductor temperature of 85°C for one third of their installed life, (i.e. an allotted life of 15 years) with short excursions to 105°C.


Edition : I5
File Size : 1 file , 880 KB
Number of Pages : 188
Published : 11/30/2008

History

MODUK DEF STAN 61-12: PART 9
Published Date: 11/30/2008
Wires, Cords and Cables Electrical - Metric Units Part 9: Cables and Wires Electrical for Cables, Radio Frequency Including Limited Fire Hazard (LFH) Variants
$14.1
MODUK DEF STAN 61-12: PART 9
Published Date: 06/04/1993
Wires, Cords and Cables Electrical - Metric Units Part 9: Cables, Radio Frequency Including Limited Fire Hazard (LFH) Variants

Related products

MODUK DEF STAN 68-113
Published Date: 12/28/2012
Silicon, Powdered
$1.2
MODUK DEF STAN 22-006
Published Date: 08/14/2019
Specification for Ozone Resistant Natural Rubber
$1.2
MODUK DEF STAN 91-7
Published Date: 08/01/1993
Reference Diesel, High Sulphur
$1.2

Best-Selling Products

DICOM PS 3.10
Published Date: 01/01/2007
Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange
DICOM PS 3.10
Published Date: 01/01/1998
Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange
DICOM PS 3.10
Published Date: 01/01/1999
Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange
DICOM PS 3.10
Published Date: 01/01/2003
Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange
DICOM PS 3.10
Published Date: 01/01/1995
Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange
DICOM PS 3.10
Published Date: 01/01/2006
Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange