NG PS(T) 068 PDF

NG PS(T) 068 PDF

Name:
NG PS(T) 068 PDF

Published Date:
06/01/2006

Status:
[ Revised ]

Description:

Policy Statements - Low Voltage Alternating Current (LVAC) Auxiliary Supplies for Transmission Substations

Publisher:
National Grid

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
ng-ps-t-068_2813701

Choose Document Language:
0
Need Help?

PURPOSE AND SCOPE

The normal operational security of a transmission substation is dependent on the availability of its auxiliary LVAC supplies to drive site assets such as transformer tap changers and cooling, air compressors motor circuits and site battery chargers.

The ideal is to provide LVAC diversity to site, that is to have site supplies which are independent and of high security. In achieving this, normal site operations will be maintained in the event of the loss of the permanent LVAC supply under fault conditions.

For some time now it has been recognised by National Grid that following a major system disturbance, when large parts of the transmission system may become islanded, substation auxiliary supplies reliability and availability plays a major role in the recovery of the system back to normality.

Substation LVAC supplies are derived from combinations of the following feeder arrangements:

  • On-site aux or earthing transformers - permanent supply.
  • An adjacent Generating Substation - permanent supply.
  • A local Distribution Network Operator (DNO) - permanent supply.
  • By on-site diesel generating set(s) - standby supply.

This policy details the LVAC connection strategy at both new substations and legacy substations where retrospective enhancement or refurbishment work on the auxiliary supplies is planned.


Edition : 2
Number of Pages : 3
Published : 06/01/2006

History

NG PS(T) 068
Published Date: 01/01/2015
Policy Statements - Low Voltage Alternating Current (LVAC) Auxiliary Supplies for Transmission Substations
55.20 €
NG PS(T) 068
Published Date: 06/01/2006
Policy Statements - Low Voltage Alternating Current (LVAC) Auxiliary Supplies for Transmission Substations

Related products

NG PS(T) 011
Published Date: 01/01/2015
Policy Statements - Alternative Use of Overhead Line Towers
55.20 €
NG SCT 20.12.15
Published Date: 08/01/2000
Site Commissioning Tests - SCHWEITZER SEL 321-2 Distance Protection with Integral Signalling
55.20 €
NG CH 10
Published Date: 06/01/2015
Commissioning Handbook - Primary and Secondary Injection Requirement for an Additional Circuit of High Impedance Circulating Current Busbar Protection with Single (Duplicated) Relays per Zone
55.20 €
NG TS 3.06.02
Published Date: 10/01/1998
National Grid Technical Specifications - Protection for Auto-Transformers
55.20 €

Best-Selling Products

NAGDM 105-1998
Published Date: 01/01/1998
American National Standard - Test Method for Thermal Transmittance and Air Infiltration of Garage Doors
16.20 €
NAGDM 106-1988
Published Date: 01/01/1988
Proposed American National Standard - Official Color Codes for Torsion and Extension Springs
16.20 €