Description:

Technical Specifications - System for Lock-Out of Delayed Automatic Reclosure for Feeder Circuits With Sections of Cable Or Gib/Gil

Publisher:
National Grid

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$275.7
Need Help?

PURPOSE AND SCOPE

The Technical Specifications for all new plant, equipment, apparatus and services, for use on the National Grid UK Electricity Transmission system are contained in a three level hierarchy of documents. Level 1 covers ratings and general requirements, Level 2 covers major plant categories and Level 3 covers specific related plant functions.

This document is a Level 3 specification, which describes the functional and performance requirements for a system to lock-out delayed automatic reclosure (DAR) sequences following the occurrence of a cable, gas insulated busbar (GIB) or gas insulated line (GIL) fault on a composite overhead line (OHL) and cable/GIB/GIL circuit.

PS(T) 010 , Application and Protection Setting Policy for the National Grid UK Transmission System defines when cable/GIB/GIL lockout should be applied. It must be emphasised that the default position for any particular installation is not to apply a DAR lockout system, it should only be applied where a suitable risk assessment has determined there is an unacceptable level of danger to National Grid staff or the General Public from a potential reclosure onto a faulted cable or GIL/GIB section.

This specification refers to Cable DAR Lockout in the sections below; it is equally applicable to GIB or GIL DAR Lockout.


Edition : 1
File Size : 1 file , 35 KB
Number of Pages : 8
Published : 06/01/2013

History


Related products

NG TS 3.06.17
Published Date: 11/01/1998
Technical Specifications (NGTS) - Protection for Quadrature Boosters
$55.2
NG UKBP/TP 162
Published Date: 12/01/2018
UK Business Procedure/Transmission Procedures - Contingency Plans in Case of Failure of Numerical Busbar Protections
$138
NG TS 3.09.04
Published Date: 09/01/1992
Technical Specifications (NGTS) - Metering Voltage Failure Alarm Relays (MVFAs)
$55.2
NG TS 3.24.40
Published Date: 03/01/2000
National Grid Technical Specifications - Cross Site Communication Links for Teleprotection
$55.2

Best-Selling Products

SAA/SNZ HB 104:1997
Published Date: 01/01/1997
A guide to year 2000 compliance
$28.116
SAA/SNZ HB 76:2010
Published Date: 08/19/2010
Dangerous Goods - Initial Emergency Response Guide
$20.196
SAA/SNZ HB1:1994
Published Date: 10/17/1994
TECHNICAL DRAWING for students
$8.712
SAA/SNZ HB18.43.1:1998
Published Date: 09/05/1998
Guidelines for third-party certification and accreditation Guide 43 - Proficiency testing by interlaboratory comparisons, Part 1: Development and operation of proficiency testing schemes
$4.95
SAA/SNZ HB18.43.2:1998
Published Date: 09/05/1998
Guidelines for third-party certification and accreditation - Guide 43 - Proficiency testing by interlaboratory comparisons, Part 2: Selection and use of proficiency testing schemes by laboratory accreditation bodies
$2.376
SAA/SNZ HB18.58:1993
Published Date: 01/01/1993
Guideline for third-party certification and accreditation, Part 58: Calibration and testing laboratory accreditation systems - General requirements for operation and recognition
$2.376