3337 -- Secondary Heat Transfer in Heat Pumps PDF

3337 -- Secondary Heat Transfer in Heat Pumps PDF

Name:
3337 -- Secondary Heat Transfer in Heat Pumps PDF

Published Date:
1990

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The effects on heat pump performance of secondary heat transfer in heat pumps were investigated using numerical models. An interchanger was shown to improve heat pump performance by increasing the output by approximately 4% and the coefficient of performance (COP) by approximately 2%. The recovery of heat transferred from the compressor by enclosing the compressor together with the accumulator in an insulated housing was shown to improve heat pump performance by increasing the output by approximately 4% and the COP by approximately 1%. The reduction of heat transfer from a compressor using liquid injection into the compressor inlet was shown to have an adverse effect on compressor performance. It was shown that heat transfer within a compressor has a major effect on its performance. It was also shown that heat and mass transfer in a reversing valve has a small adverse effect on heat pump performance. The reasons for the beneficial or adverse effect were evident from the simulated detailed heat pump performance data.

 

KEYWORDS: heat flow, secondary, heat pumps, performance, coefficient of performance, calculating, compressors, casing, heat exchangers, finned tube heat exchangers.


File Size : 1 file , 1.6 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-18406
Published : 1990

History


Related products


Best-Selling Products

IEC/TR 60034-16-2 Ed. 1.0 b:1991
Published Date: 02/15/1991
Rotating electrical machines - Part 16: Excitation systems for synchronous machines - Chapter 2: Models for power system studies
$88.746
IEC/TR 60068-3-12 Ed. 2.0 b:2014
Published Date: 10/17/2014
Environmental testing - Part 3-12: Supporting documentation and guidance - Method to evaluate a possible lead-free solder reflow temperature profile
$39.9
IEC/TR 60068-3-12 Ed. 3.0 en:2022
Published Date: 10/01/2022
Environmental testing - Part 3-12: Supporting documentation and guidance - Method to evaluate a possible lead-free solder reflow temperature profile
$83.4
IEC/TR 60068-3-15 Ed. 1.0 en:2024
Published Date: 02/01/2024
Environmental testing – Part 3-15: Supporting documentation and guidance – Vacuum-assisted reflow soldering
$70.2
IEC/TR 60068-3-82 Ed. 1.0 en:2024
Published Date: 08/01/2024
Environmental testing – Part 3-82: Supporting documentation and guidance – Confirmation of the performance of whisker test method
$115.8
IEC/TR 60071-4 Ed. 1.0 en:2004
Published Date: 06/23/2004
Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks
$136.5