3925 -- System Performance Comparison of R507 with R502 PDF

3925 -- System Performance Comparison of R507 with R502 PDF

Name:
3925 -- System Performance Comparison of R507 with R502 PDF

Published Date:
1995

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

R-507 is an azeotropic of HFC-125/HFC-143a (50%/50%) and is a long-term, zero ozone depletion potential (ODP) replacement for CFC-containing low-temperature refrigerant R502. A series of system performance tests has been completed comparing R507 with R502. The tests were carried out under controlled conditions in a well-instrumented alternative refrigerants test facility, using an open drive reciprocating compressor and counterflow tube-in-tube heat exchangers. Measurements were conducted at two different condensing temperatures; 54.4degC (130.0degF) and 43.3degC (110.0degF). The refrigerant evaporating temperature was varied over a range of -30.0degC to -15.0degC (-22degF to 5.0degF). The degree of liquid subcooling at the condenser outlet was varied between 6.0degC and 18degC (10.8degF and 32.4degF). Test data were used to compare important compressor performance characteristics including shaft power, pressure ratio and compressor discharge temperature. System performance characteristics were also measured, including evaporator capacity, refrigerant mass flow, and cooling coefficient of performance (COP). The effect of additional liquid subcooling on the evaporator capacity and COP was also evaluated. The relative evaporator capacity of R507 compared to R502 was found to range from 0.95 to 1.05, depending on the operating conditions and the amount of liquid subcooling present. For all the conditions tested, R507 was less energy efficient than R502. The relative COP of R507 ranged from 0.87 to 0.97.

KEYWORDS: year 1995, performance, comparing, refrigerants, replacing, R507, R502, azeotropic, testing, reciprocating compressors, counter flow heat exchangers, tube in tube heat exchangers, measuring, subcooling, condensers, properties, coefficient of performance, evaporators, efficiency


File Size : 1 file , 860 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-17128
Published : 1995

History


Related products


Best-Selling Products

ABMA 10-1989
Published Date: 06/05/1989
Metal Balls
ABMA 11:1990 (R2008)
Published Date: 06/17/1990
Load Ratings and Fatigue Life for Roller Bearings
ABMA 11:2014 (R2020)
Published Date: 2014
Load Ratings and Fatigue Life for Roller Bearings
$16.5
ABMA 12.1:1992 (S2020)
Published Date: 04/06/1992
Instrument Ball Bearings - Metric Design
$16.5
ABMA 12.2:1992 (S2020)
Published Date: 04/06/1992
Instrument Ball Bearings - Inch Design
$16.5
ABMA 13:1987 (S2010)
Published Date: 09/02/1987
Rolling Bearing Vibration and Noise (Methods of Measuring)