AC-02-14-1 -- Performance Evaluation of a Reciprocating Chiller Using Experimental Data and Model Predictions for Fault Detection and Diagnosis PDF

AC-02-14-1 -- Performance Evaluation of a Reciprocating Chiller Using Experimental Data and Model Predictions for Fault Detection and Diagnosis PDF

Name:
AC-02-14-1 -- Performance Evaluation of a Reciprocating Chiller Using Experimental Data and Model Predictions for Fault Detection and Diagnosis PDF

Published Date:
2002

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Detecting degradation faults remains a challenge in spite of the advances in monitoring and controls software. Basic monitoring equipment can be used to detect the most obvious faults. However, degradation faults can have a small effect on the system's ability to control building conditions and occupants' comfort while having a large effect on energy consumption and expected equipment life. Research conducted over the past decade has sought to enable a building energy management system (BEMS) with embedded fault detection and diagnostic software to identify typical system faults, generating warning alarms if the system performance begins to degrade.

This paper presents a model-based approach to fault detection and diagnostics for a reciprocating chiller and examines the performance of the method using simulation and experimental data. MATCH (model-based assessment tool for chillers), the implementation of the classifier and expert rule set in the software, was first applied to fault-free and faulty experimental data using seven performance indices. As expected, the ability to detect faults is influenced by the severity of the fault and the operating conditions. MATCH successfully detected and diagnosed condenser fouling, refrigerant under-charge, and refrigerant overcharge at a fault level of 20% or greater and evaporator fouling and liquid line restriction at a fault level of 30% or greater. Results highlight the difficulty of detecting and diagnosing a liquid line restriction for systems using thermal expansion devices.

Units: Dual

 


File Size : 1 file , 1.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 15
Product Code(s) : D-7021
Published : 2002

History


Related products


Best-Selling Products

FORD AWX
Published Date: 12/01/1993
WIRE, TAMPICO, AND SYNTHETIC FILAMENT POWER WHEEL BRUSHES APPLICATIONS AND GENERAL INFORMATION
$9
FORD B2BBX
Published Date: 09/01/1991
ONE-STEP PAINT LINE CLEANING PROCEDURE
$9
FORD B2F1
Published Date: 02/01/1978
ANODIC ELECTROCOATING SYSTEM CLEANING AND MAINTENANCE
$9
FORD B2GX
Published Date: 04/01/1984
PAINT BAKE OVENS CLEANING AND MAINTENANCE
$9
FORD BAX-1
Published Date: 07/01/1977
PAINT SPRAYING SYSTEMS, SMALL PARTS, AUTOMATIC
$9
FORD BAX-2
Published Date: 07/01/1985
PAINT SPRAY BOOTH BACK SECTION ACCEPTANCE TEST
$9