AT-19-011 -- HVAC System Air Leakage Requirements for Deep Energy Retrofit Projects PDF

AT-19-011 -- HVAC System Air Leakage Requirements for Deep Energy Retrofit Projects PDF

Name:
AT-19-011 -- HVAC System Air Leakage Requirements for Deep Energy Retrofit Projects PDF

Published Date:
2019

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
One of the major outcomes of the recently completedInternational Energy Agency (IEA) Energy and Buildingsand Communities (EBC) Annex 61 “Business and TechnicalConcepts for Deep Energy Retrofit in Public Buildings” is aTechnical Guide (EBC 2017a) that contains a list of coreenergy efficiency technologies generated from the results ofcase studies (EBC 2017b), from surveys and discussionsconducted at the ASHRAE Technical Committee (TC) 7.6,“Federal Buildings” working group meetings in 2013 and2014, and from previous experience and research conductedby the EBC Annex 61 team members. These technologies,when applied together (as a bundle), will reduce total buildingsite energy use by about 50% (including plug loads).Technical characteristics of these building retrofit technologies,grouped into a core technologies bundle, have beenstudied through modeling and life cycle cost (LCC) analysisfor representative national climate conditions. Among thesetechnologies are those related to the building envelope; lighting;and heating, ventilating, and air-conditioning (HVAC)systems.When a building undergoes a deep energy retrofit (DER)that is conducted as part of a major renovation project, the ductsystem is usually replaced. Replacing it with a well-insulatedand airtight system is one of the most cost-effective energy efficiencymeasures available. One reason is that the airflowsthrough air-handling units (AHUs) connected to ducts must besufficient to compensate for air leakage involving ducts andduct-mounted components (HVAC system air leakage). TheseAHU airflows account for a large fraction of the energy use inbuildings. For example, in the United States,HVACsystem airleakage is ranked as the primary source of energy inefficiencyin commercial buildings; it wasted an estimated $2.9 billion in2005 (Mills 2009). Based on research results and experiencefrom the United States and around the world (especially inScandinavia), this paper provides recommendations on costeffectivetargets for ductwork airtightness and a quality assuranceprocess for achieving these targets.
File Size : 1 file , 1.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 11
Product Code(s) : D-AT-19-011
Published : 2019
Units of Measure : Dual

History


Related products


Best-Selling Products

prNS 2964
Published Date: 10/24/2000
Plastics pipes - Pipes and fittings with structured wall of polyethylene (PE) for underground non-pressure systems for drainage and sewerage
prNS 2965
Published Date: 10/24/2000
Plastics pipes - Pipes and fittings with structured wall of polypropylene (PP) for underground non-pressure systems for drainage and sewerage
prNS 2966
Published Date: 10/24/2000
Plastics pipes - Pipes and fittings with structured wall of unplasticised poly(vinyl chloride) (PVC-U) for underground non-pressure systems for drainage and sewerage
prNS 2967
Published Date: 06/01/2001
Cable ducts of plastics with smooth solid wall pipe
prNS 2970
Published Date: 09/06/2004
Solid Wall cable ducting of thermoplastics for embedding
prNS 3563
Published Date: 07/01/2002
Ventilation for buildings - Design methodes for indoor climate