BA-92-03-4 -- Measured Energy Consumption of Variable-Air-Volume Fans Under Inlet Vane and Variable-Speed-Drive Control PDF

BA-92-03-4 -- Measured Energy Consumption of Variable-Air-Volume Fans Under Inlet Vane and Variable-Speed-Drive Control PDF

Name:
BA-92-03-4 -- Measured Energy Consumption of Variable-Air-Volume Fans Under Inlet Vane and Variable-Speed-Drive Control PDF

Published Date:
1992

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Variable-speed drives (VSDs) are a popular retrofit for variable-air-volume ventilation fans, yet few measurements of annual energy savings have been performed. To eliminate the need for a year of pre-retrofit and a year of post-retrofit data, one previously developed measurement technique (applied to two air handlers in a single building) relied on correlations of fan power to volumetric flow rates combined with histograms of flow data. There is a need for more performance measurements, particularly when flow data are not available. To the extent that the demand for air flow depends on thermal gains and building occupancy and use patterns, fan power may be correlated to these directly. One advantage to this approach is that knowledge of temperature and solar loading profiles, as well as expected occupancies, may be obtained more easily than is the case for air flow. Fan power is modelled as a function of outside temperature only for four variable-air-volume systems outfitted with VSD controllers. The curves developed are used to estimate the savings of VSDs over variable inlet vanes in the same air handlers. Practical problems, such as filtering data and the choice of sampling intervals, are discussed.

KEYWORDS: measuring, energy consumption, variable volume air conditioning, fans, variable speed motors, controls, energy conservation, air handling units, performance, air flow, heat gain, buildings, occupancy, temperature, solar radiation, calculating, outdoor temperature, ventilation, electricity consumption


File Size : 1 file , 1.1 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-17853
Published : 1992

History


Related products


Best-Selling Products

Ethernet : The Definitive Guide
Published Date: 02/01/2000
$13.5
Excel Annoyances
Published Date: 01/01/1999
$9
XML Pocket Reference
Published Date: 08/01/1999
$2.7