Thermostat setback at night is widely used during the heating season to achieve energy savings. The time required in the morning to recover from overnight temperature setback is an important characteristic of a heating plant.

Various performance aspects of residential space conditioning systems are being assessed in tests at two unoccupied research houses in the Washington, D.C. area. Tests were conducte during the 1987-1988 heating season using four commercially available gas-fired and electric resistance furnaces sized 20% to 103% over the design heat loss for the houses. The thermostat setpoint in the houses was 72°F (22.2°C) and an eight-hour night setback of 12°F( 6.7°C) was implemented. The presence of occupants was simulated by use of heat and moisture generators, lighting, and scheduled operation of appliances. The research houses are moderately furnished to approximate conditions of occupancy for a family of three.

At an average indoor-outdoor temperature difference (delta T) of 50°F during the setback period, the morning pickup time was two hours for a gas furnace oversized by 37% and and 0.9 hours for a gas furnace oversized by 103%. Morning pickup times were linearly correlated with a wide range of delta T for each furnace. Test results indicated that the morning pickup times for the furnaces tested were longer than those previously published in the ASHRAE Handbook. Results are presented and discussed as they relate to furnace sizing for acceptable pickup times.


File Size : 1 file , 650 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-CH-89-20-1
Published : 1989

History


Related products


Best-Selling Products

ICEA P-117-734-2016
Published Date: 02/23/2016
Ampacities For Single-Conductor Solid Dielectric Power Cable 15 kV Through 35 kV
$90
ICEA P-117-734-2022
Published Date: 07/06/2022
Ampacities For Single-Conductor Solid Dielectric Power Cable 15 kV Through 35 kV
$96
ICEA P-123-739-2018
Published Date: 01/18/2018
GUIDE TO ESTABLISH ELECTRICAL TEST METHODS FOR NON-CONDUCTING JACKET MATERIALS FOR POWER CABLES RATED 5 TO 500 KV
$22.5
ICEA P-124-736-2021
Published Date: 06/03/2021
Code Words for 600 Volt Underground Distribution Cables
$13.5
ICEA P-127-737-2021
Published Date: 06/03/2021
Code Words for Overhead Aluminum Covered Conductors and 600 Volt Overhead Cables
$13.5
ICEA P-136-726-2024
Published Date: 2024
Guide for Pellet Inspection Systems for Unfilled Power Cable Insulation Compound
$29.1