CH-89-22-2 -- Cold Air Distributions with Ice Storage PDF

CH-89-22-2 -- Cold Air Distributions with Ice Storage PDF

Name:
CH-89-22-2 -- Cold Air Distributions with Ice Storage PDF

Published Date:
1989

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Cold air/water HVAC systems [40°F (4.4°C)] have been developed for use with ice thermal storage because (1) they require one-third to one-half as much primary air as 40°F(4.4°C) all-air HVAC systems, (2) they control humidity and temperature separately and thus can be applied in a much broader range of facilities without overdrying the air, and (3) they are lower in both first cost and energy cost than the all-air systems, making ice storage equipmenat more practical option. This paper describes 40°F (4.4°C) air/water VAV systems and compares the following HVAC systems in terms of electric demand (day vs. night), energy usage, energy cost, and first cost:

  • 40°F (4.4°C) air/water VAV system with partial ice storage
  • 40°F (4.4°C) air/water VAV system with full ice storage
  • 40°F (4.4°C) all-air VAV system with partial ice storage
  • 40°F (4.4°C) all-air VAV system with full ice storage
  • 55°F (12.8°C) all-air VAV system

Also examined are (1) the impact of different utility rate structures on the economics of the alternative ice thermal storage HVAC systems and (2) a specific retail store application of a 40°F (4.4°C) air/water system with partial ice thermal storage.

Conclusions include the following: (1) where there is only a small spread between the utility’s day and night energy usage rates, a partial ice storage air/water system can produce a lower annual energy cost than a full ice storage system; and (2) the 40°F (4.4°C) air/water partial ice system is the most cost-effective of the five HVAC systems compared, in each of four utility rate scenarios. It is lower in first cost than the alternative cold-air systems and approximately equal in first cost to the conventional all-air VAV system (lower in the case of a large building, higher in the case of a small building); and the annual energy cost is 50% to 57% less than that of the conventional 55°F (12.8°C) system and 29% to 32% less than that of a 40°F (4 .4°C) all-air partial-ice system.


File Size : 1 file , 1.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-CH-89-22-2
Published : 1989

History


Related products


Best-Selling Products

CAN/CSA-ISO/IEC/IEEE 12207:18 (R2023)
Published Date: 12/01/2018
Systems and software engineering - Software life cycle processes (Adopted ISO/IEC 12207:2008, second edition, 2008-02-01)
$71.4
CAN/CSA-ISO/IEC/IEEE 12207-2:21
Published Date: 07/01/2021
Systems and software engineering - Software life cycle processes - Part 2: Relation and mapping between ISO/IEC/IEEE 12207:2017 and ISO/IEC 12207:2008 (ISO/IEC/IEEE 12207-2:2020, IDT)
$63.6
CAN/CSA-ISO/IEC/IEEE 14764:22
Published Date: 09/15/2022
Software engineering - Software life cycle processes - Maintenance (Adopted ISO/IEC/IEEE 14764:2022, third edition, 2022-01)
$51
CAN/CSA-ISO/IEC/IEEE 15026-1:20
Published Date: 03/01/2020
Systems and software engineering - Systems and software assurance - Part 1: Concepts and vocabulary (Adopted ISO/IEC 15026-1:2013, first edition, 2013-11-01)
$45
CAN/CSA-ISO/IEC/IEEE 15026-4:22
Published Date: 03/01/2022
Systems and software engineering - Systems and software assurance - Part 4: Assurance in the life cycle
$51.6
CAN/CSA-ISO/IEC/IEEE 15289:20
Published Date: 07/01/2020
Systems and software engineering - Content of life-cycle information items (documentation) (Adopted ISO/IEC/IEEE 15289:2019, fourth edition, 2019-07)
$60