CH-95-05-2 -- Analysis of a Field-Installed Hybrid Solar Desiccant Cooling System PDF

CH-95-05-2 -- Analysis of a Field-Installed Hybrid Solar Desiccant Cooling System PDF

Name:
CH-95-05-2 -- Analysis of a Field-Installed Hybrid Solar Desiccant Cooling System PDF

Published Date:
1995

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Monitors and assesses the performance of a commercial hybrid solar solid desiccant air-conditioning system in a high-humidity restaurant application. air is heated in the regeneration section by a heat recirculator coil, a condenser waste heat recovery coil, and a solar cell, accounting for roughly 27%, 24%, and 49% of the regeneration heat, respectively, when solar energy is available. The specific humidity change across the desiccant wheel varies from 4 to 90gr/lb (0.57 to 12.86g/kg) over the 108degF to 197degF (42.2degC to 91.7degC) regeneration temperature range. The coefficient of performance (COP), defined as the usable cooling capacity divided by the heat input, increased from 0.2 to 1.0 at the rate of 0.01 for every 10degF rise in the regeneration temperature. The results from this project provide much valued field data as well as a design basis for future work. The desiccant unit supplies conditioned ventilation air to two conventional packaged vapour-compression air-conditioning units, thereby forming a hybrid system. The effect of this arrangement on the performance of the vapour-compression units was investigated. The desiccant unit accounts for about one-fourth of the dehumidification capacity available to the restaurant. The cooling capacity of the desiccant cooling system varies over the day, mostly with solar insolation and to a lesser degree with ambient relative humidity. The desiccant unit provides an average capacity of 21.560Btu/h (6.32kW). Since the retrofit of the hybrid system, the kitchen air temperature has decreased by about 15degF and specific humidity has decreased by about 30gr/lb (4.29g/kg).

KEYWORDS: year 1995, desiccants, cooling, solar energy, heat recovery, restaurants, humidity, relative humidity, kitchens, air temperature, insolation, solar cooling, performance, monitoring, electricity consumption, energy consumption, coefficient of performance, unit air conditioners, natural gas, comparing, latent heat.


File Size : 1 file , 1.2 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-16850
Published : 1995

History


Related products


Best-Selling Products

SNV RFC 7723
Published Date: 01/01/2016
Port Control Protocol (PCP) Anycast Addresses
$9.6
SNV SIA 196*SN 531196
Published Date: 11/01/1998
Baulueftung im Untertagbau
$44.7
SNV SIA 196
Published Date: 11/01/1998
Ventilation des chantiers souterrains
$44.7
SNV SIA 197/1*SN 505197/1
Published Date: 10/01/2004
Projektierung Tunnel Bahntunnel
$38.4
SNV SIA 197/2*SN 505197/2
Published Date: 10/01/2004
Projektierung Tunnel Strassentunnel
$38.4
SNV SIA 197*SN 505197
Published Date: 10/01/2004
Projektierung Tunnel Grundlagen
$41.1