CH-99-14-3 -- Comparison of Residential Air Infiltration Rates Predicted by Single-Zone and Multizone Models PDF

CH-99-14-3 -- Comparison of Residential Air Infiltration Rates Predicted by Single-Zone and Multizone Models PDF

Name:
CH-99-14-3 -- Comparison of Residential Air Infiltration Rates Predicted by Single-Zone and Multizone Models PDF

Published Date:
1999

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Residential air infiltration rates predicted by a detailed multizone computational model are compared with those predicted by a single-zone model. The multizone model is created using the public domain program CONTAM96, which allows the user to break the house into a number of zones connected to one another and the outdoors by leakage paths with user-defined characteristics. Actual floor plans for a ranch-style house and typical published leakage characteristics of residential building components are used to construct a very detailed model with roughly 2,000 zones and 7,000 leakage paths. The leakage path configuration of this multizone model is then validated by performing fan pressurization tests on two houses constructed according to the floor plan used to develop the computational model. At pressure differences typical of infiltration conditions, the leakage of the multizone model is in between that of the two identical houses. Infiltration rates computed by the multizone model for representative outdoor temperatures and wind speeds are then compared to those predicted by the single-zone LBL model. Four ventilation systems are modeled: no mechanical ventilation or exhaust, supply fan only, exhaust fan only, and balanced supply and exhaust fans. Comparisons are initially made based on the single-zone model predictions using typical assumptions. The multizone computational model is then used to calculate more precise wind parameters and building leakage characteristics for use in the single-zone model, and the resulting infiltration is again compared with that predicted by the multizone model. These comparisons show that the predictions of both models are sensitive to the choice of wind-related parameters and that the assumption that leakage is evenly distributed throughout the building envelope has little effect on the predictions of the single-zone model. The predictions of the single-zone model most closely match those of the multizone model when flows are added using a quadrature method that takes into account the flow exponent obtained using the multizone model.

Units: Dual


File Size : 1 file , 290 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 13
Product Code(s) : D-7609
Published : 1999

History


Related products


Best-Selling Products

MHI CMAA 70
Published Date: 01/01/2015
Specification for Top Running Bridge and Gantry Type Multiple Girder Electric Overhead Traveling Cranes
$37.8
MHI CMAA 70
Published Date: 01/01/2020
Specification for Top Running Bridge and Gantry Type Multiple Girder Electric Overhead Traveling Cranes
$45
MHI CMAA 74
Published Date: 01/01/2020
Specifications for Top Running and Under Running Single Girder Electric Traveling Cranes Utilizing Under Running Trolley Hoist
$45
MHI CMAA 74
Published Date: 01/01/2015
Specification for Top Running and Under Running Single Girder Electric Overhead Cranes Utilizing Under Running Trolley Hoist
$37.8
MHI CMAA 78
Published Date: 01/01/2014
Standards and Guidelines for Professional Services Performed On Overhead and Traveling Cranes and Associated Hoisting Equipment (Revised 2015)
$14.4
MHI CMAA 79
Published Date: 01/01/2012
Crane Operator's Manual
$5.4