DE-05-11-6 - Thermal Profile of a High-Density Data Center: Hot Spot Heat Fluxes of 512 W/ft2 PDF

DE-05-11-6 - Thermal Profile of a High-Density Data Center: Hot Spot Heat Fluxes of 512 W/ft<sup>2</sup> PDF

Name:
DE-05-11-6 - Thermal Profile of a High-Density Data Center: Hot Spot Heat Fluxes of 512 W/ft2 PDF

Published Date:
2005

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The performance of computing equipment continues to increase following Moore’s law of doubling the performance every 18 months. The performance improvements achieved by the semiconductor and computer manufacturers stand alone among any other industry for achieving increased performance over a sustained period of time. However, these increases in performance have a downside in that it has caused a significant increase in heat dissipated by the computing equipment, such that it is becoming very difficult to cool these systems in data centers or telecommunications rooms. Some of the highest powered systems are dissipating upward of 2500 W/ft2(27,000 W/m2) based on the equipment footprint. When systems dissipate this amount of heat and then are clustered together within a data center, significant cooling challenges can result. This paper describes the thermal profile of a 76 ft × 98 ft (23.2 m × 29.9 m) data center and the measurement techniques employed to fully capture the detailed thermal environment. In a portion of the data center(16 ft × 26 ft 4.9 m ×7.9 m), which encompasses very high powered servers, the heat flux is 512 W/ft2(5500 W/m2). Most racks within this area dissipated approximately 19 kW. Detailed measurements were taken in this data center of electronic equipment power usage, perforated floor tile airflow, cable cutout airflow, computer room air-conditioning (CRAC) airflow, and electronic equipment inlet air temperatures. In addition to these measurements, the physical features of the data center were recorded such that a detailed CFD model could be employed to compare the results (this will be the subject of a follow-up paper).


File Size : 1 file , 880 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-26984
Published : 2005

History


Related products


Best-Selling Products

ETSI Draft EN 301 908-13
Published Date: 11/01/2021
IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 13: Evolved Universal Terrestrial Radio Access (E-UTRA) User Equipment (UE)
$9.81
ETSI EG 200 053
Published Date: 06/01/2004
Electromagnetic compatibility and Radio spectrum Matters (ERM); Radio site engineering for radio equipment and systems
$9.81
ETSI EG 200 234
Published Date: 02/01/2000
Telecommunications security; A guide to specifying requirements for cryptographic algorithms
21.80 21.31 you save 0.49
ETSI EG 200 351
Published Date: 09/01/1997
ETSI object identifier tree; Rules and registration procedures
$4.164
ETSI EG 200 351
Published Date: 09/01/1998
ETSI object identifier tree; Rules and registration procedures
$4.164
ETSI EG 200 351
Published Date: 10/01/1999
ETSI object identifier tree; Rules and registration procedures
17.83 17.34 you save 0.49