Determining Moisture Source due to Wind Driven Rain for Input to Hygrothermal Simulations Using Experimental Methods PDF

Determining Moisture Source due to Wind Driven Rain for Input to Hygrothermal Simulations Using Experimental Methods PDF

Name:
Determining Moisture Source due to Wind Driven Rain for Input to Hygrothermal Simulations Using Experimental Methods PDF

Published Date:
2019

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
Determining long-term durability of building envelope components and assemblies in response to moisture loads can be completed using several methods, including: experiments, long term exposure studies, and hygrothermal simulations. If multiple climate locations or building envelope assemblies are under consideration, hygrothermal simulation methods are typically preferred by building practitioners as they can be completed more rapidly and with less expense as compared to experimental or long-term exposure methods. However, completing hygrothermal simulations requires knowledge of material properties, interior and exterior boundary conditions, and initial simulation conditions. Beyond these inputs to the model additional information is required to account for wind-driven rain, and corresponding moisture loads arising from water entry to the building envelope assembly. Fortunately, standards exist to guide a user through a systematic and repeatable method of conducting hygrothermal simulations, such as ASHRAE S160 and the "Guideline on design for durability of building envelopes". The ASHRAE S160 standard includes an approach to incorporate the effects of water entry due to wind-driven rain as a moisture source in hygrothermal simulations. Specifically, if knowledge of the wind-driven rain response characteristics of the cladding in the building envelope assembly is not known by the building practitioner, ASHRAE S160 recommends using 1% of the wind-driven rain as the moisture source.This paper seeks to provide further information towards an experimental definition of the moisture source and as an example of such a definition, a vinyl clad wall for two different coastal climate locations in Canada is considered. Additionally, the influence of the experimentally determined moisture source calculation method, compared to that recommended in the ASHRAE S160 (1% of wind-driven rain), is investigated from results of hygrothermal simulation. Keywords: moisture source, wind-driven ASHRAE S160, Guideline on design for durability of building envelopes, rain, drainage, hygrothermal, modelling,
File Size : 1 file , 1000 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 11
Product Code(s) : D-Bldgs19-060
Published : 2019
Units of Measure : Dual

History


Related products


Best-Selling Products

UL 1004-10
Published Date: 02/28/2020
Standard for Pool Pump Motors
$150.6
UL 1004-1
Published Date: 09/15/2008
Rotating Electrical Machines - General Requirements
UL 1004-1
Published Date: 09/19/2012
Rotating Electrical Machines - General Requirements
$189.3
UL 1004-2
Published Date: 09/15/2008
Impedance Protected Motors
UL 1004-2
Published Date: 01/10/2014
Impedance Protected Motors
UL 1004-3
Published Date: 09/15/2008
Standard for Thermally Protected Motors