HO-18-C014 -- Application of Mobile-Internet-Based Occupancy Data in Building Energy Model Calibration: A Case Study PDF

HO-18-C014 -- Application of Mobile-Internet-Based Occupancy Data in Building Energy Model Calibration: A Case Study PDF

Name:
HO-18-C014 -- Application of Mobile-Internet-Based Occupancy Data in Building Energy Model Calibration: A Case Study PDF

Published Date:
2017

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

High-quality occupancy data is the key input parameter for building energy simulations and has a big impact on the precision and accuracy of building energy model performance. However, current approaches to get such data through the occupancy detection technology require either implementations of large-scale sensors network or sophisticated and time-consuming computational algorithms, which strongly limits the application of real-time occupancy data for building energy simulation. This paper presents an investigation of whether and how mobile-internet-based positioning data can benefit building energy simulation. This paper first briefly summarizes the pros and cons of several mainstream occupancy detection methods. Then, the principles of the proposed mobile-internet-based occupant detection method are introduced. An initial energy performance model of a complex building in Shanghai, China with a whole building simulation software is used as a case study to demonstrate the effectiveness of the proposed method. An initial calibration is conducted using the history data from the building automation system, followed by two parallel further calibration approaches. The first approach is conducted with a traditional calibration method (i.e., trial-and-error based method) and the second one uses the mobile-internet-based occupancy data. The simulation results show that using mobile-internet based occupancy data can help improve the building model prediction accuracy and simplify the calibration process compared with traditional trial-and-error approaches.


File Size : 1 file , 2.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-HO-18-C014
Published : 2017
Units of Measure : Dual

History


Related products


Best-Selling Products

LPI 175
Published Date: 01/01/2008
Standard of Practice for the Design - Installation - Inspection of Lightning Protection Systems, 2008 Edition
LPI 175
Published Date: 2011
Standard of Practice for the Design - Installation - Inspection of Lightning Protection Systems, 2011 Edition
$14.7
LPI 175
Published Date: 2014
Standard of Practice for the Design - Installation - Inspection of Lightning Protection Systems, 2014 Edition
$14.7