Name:
ITU-T H.810 PDF
Published Date:
12/01/2013
Status:
[ Revised ]
Publisher:
International Telecommunication Union-T
Scope of the CDG 2013
These CDG include guidelines for the TAN-IF, PAN-IF (wired, standard wireless and low-power wireless), LAN-IF (sensor LAN), WAN-IF (data upload) and HRN-IF.
The TAN-IF (near-field communications, NFC) interface guidelines are defined for the following device specializations: pulse oximeter, blood pressure monitor, thermometer, weighing-scales, glucose meter, cardiovascular fitness, step counter, strength fitness, activity hub, adherence monitor, peak flow meter, fall sensor, motion sensor, enuresis sensor, contact closure sensor, switch sensor, dosage sensor, water sensor, smoke sensor, property exit sensor, temperature sensor, usage sensor, PERS sensor, CO sensor, gas sensor, heart-rate sensor, Basic 1-3 lead ECG sensor, body composition analyser, INR meter.
The PAN-IF interface guidelines for PAN wired (USB) and PAN standard wireless (Bluetooth) are defined for the following device specializations: pulse oximeter, blood pressure monitor, thermometer, weighing-scales, glucose meter, cardiovascular fitness, step counter, strength fitness, activity hub, adherence monitor, peak flow meter, fall sensor, motion sensor, enuresis sensor, contact closure sensor, switch sensor, dosage sensor, water sensor, smoke sensor, property exit sensor, temperature sensor, usage sensor, PERS sensor, CO sensor, gas sensor, heart-rate sensor, Basic 1-3 lead ECG sensor, body composition analyzer, INR meter.
The PAN-IF interface guidelines for LP wireless PAN (Bluetooth LE) are defined for the following: thermometer, heart-rate sensor, blood pressure monitor, glucose meter.
The sensor-LAN (ZigBee) interface guidelines are defined for the following device specializations: pulse oximeter, blood pressure monitor, thermometer, weighing-scales, glucose meter, cardiovascular fitness, step counter, strength fitness, activity hub, adherence monitor, peak flow meter, fall sensor, motion sensor, enuresis sensor, contact closure sensor, switch sensor, dosage sensor, water sensor, smoke sensor, property exit sensor, temperature sensor, usage sensor, PERS sensor, CO sensor, gas sensor, heart-rate sensor, Basic 1-3 lead ECG sensor, Body composition analyser, INR meter.
The WAN-IF guidelines for upload of device observations across a wide area network are defined. The HRN-IF guidelines for a health reporting interface towards (other) enterprise systems are defined.
| Edition : | 13 |
| Number of Pages : | 382 |
| Published : | 12/01/2013 |