LB-07-034 -- Experimental Evaluation of a Downsized Residential Air Distribution System: Comfort and Ventilation Effectiveness PDF

LB-07-034 -- Experimental Evaluation of a Downsized Residential Air Distribution System: Comfort and Ventilation Effectiveness PDF

Name:
LB-07-034 -- Experimental Evaluation of a Downsized Residential Air Distribution System: Comfort and Ventilation Effectiveness PDF

Published Date:
2007

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

New challenges surrounding air-distribution effectiveness have emerged from downsizing of the HVAC systems in energy-efficient residential buildings. As a result of downsizing, the system design flow rates are significantly reduced— potentially leading to poor air mixing and undesirable spatial temperature patterns and, consequently, adversely affecting the comfort level and ventilation effectiveness. Unless these challenges are successfully met, the system downsizing trend, as well as the efforts to implement related energy-saving measures, will be undermined.

This paper examines the performance of a prevalent airdistribution configuration incorporating a high sidewall supply air diffuser and a near-floor, wall-mounted return air grille in a test room during a period of recovery from setback. To address the aforementioned issues of interest, tracer-gas tests were conducted along with spatial temperature measurements in the room. In the experiments, two levels of supply airflow rate were considered, low and high, of which the latter is comparable to the design range commonly applied in standard- practice residential buildings. The results indicated that, at the lower flow rate and velocity, both ventilation effectiveness and comfort were compromised because of stratification.

The constraints with the trace-gas instrumentation led to inconclusive results with respect to air mixing and ventilation effectiveness. To overcome this limitation, a frame of reference was introduced for a more accurate assessment of the experimental system performance. The analytical solutions for an ideal case in which the indoor air was perfectly mixed at any given instant provided the reference points for comparison.

Units: Dual


File Size : 1 file , 2.6 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-LB-07-034
Published : 2007

History


Related products


Best-Selling Products

ISO/PAS 11585:2023
Published Date: 09/01/2023
Road vehicles - Partial driving automation - Technical characteristics of conditional hands-free driving systems
$37.2
ISO/PAS 11819-4:2013
Published Date: 03/15/2013
Acoustics - Method for measuring the influence of road surfaces on traffic noise - Part 4: SPB method using backing board
$20.4
ISO/PAS 11856:2003
Published Date: 01/01/2003
Textile floor coverings - Test methods for the determination of fibre bind
$34.2
ISO/PAS 12006-3:2001
Published Date: 10/01/2001
Building construction - Organization of information about construction works - Part 3: Framework for object-oriented information exchange
$27.6
ISO/PAS 12158:2002
Published Date: 07/01/2002
Road vehicles - Braking systems - Temperature measuring methods
$20.4
ISO/PAS 12835:2013
Published Date: 12/15/2013
Qualification of casing connections for thermal wells
$75