LO-09-031 -- Discussion of Design Method and Optimization on Airflow Distribution in a Large-Space Building with Stratified Air-Conditioning System PDF

LO-09-031 -- Discussion of Design Method and Optimization on Airflow Distribution in a Large-Space Building with Stratified Air-Conditioning System PDF

Name:
LO-09-031 -- Discussion of Design Method and Optimization on Airflow Distribution in a Large-Space Building with Stratified Air-Conditioning System PDF

Published Date:
2009

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Indoor air distribution is a major concern in designing indoor thermal environment of a large space, which is different from normal buildings. Today, stratified air conditioning is acommon choice for large-space buildings. Indoor air distribution with the stratified air conditioning is affected by many design parameters. These parameters have direct effects on thermal comfort, environment noise and energy consumption. Selection of these parameters thus becomes the key problem indesign of indoor thermal environment in a large space. In this paper, a large-space building is taken as the study object. It was found that the cooling load varies linearly with the stratified height. The calculations of the air distributions were performed under the conditions of different stratified height, diameter and quantity of the blast nozzles. Based on calculatedresults, the alignment charts were plotted in an effort to determine the design parameters such as the height, the diameter and the number of blast nozzles and their selection range for a large-space building. According to the charts, the relationship of design parameters and their optimized selection are analyzed. It is clear that the lower the height, the less the energy consumption demand is, however, the noise level would be higher. Based on above results, an optimized and practical methodology is formulated for the design of the air distribution in a large space.

 

Units: Dual 


File Size : 1 file , 580 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 5
Product Code(s) : D-LO-09-031
Published : 2009

History


Related products


Best-Selling Products

LIA Z136.1-2007
Published Date: 03/16/2007
Safe Use of Lasers
LIA Z136.1-2014
Published Date: 2013
Safe Use of Lasers
$60.9
LIA Z136.1-2022
Published Date: 2022
Safe Use of Lasers
$67.5
LIA Z136.2-2012
Published Date: 12/19/2012
Safe Use of Optical Fiber Communication Systems Utilizing Laser Diode and LED Sources
$45
LIA Z136.3-2005
Published Date: 01/06/2005
Safe Use of Lasers in Health Care Facilities
LIA Z136.3-2011
Published Date: 12/05/2011
Safe Use of Lasers in Health Care Facilities
$47.4