NY-14-C073 -- Energy Efficiency Strategies for Hydronic Systems Through Intelligent Actuators PDF

NY-14-C073 -- Energy Efficiency Strategies for Hydronic Systems Through Intelligent Actuators PDF

Name:
NY-14-C073 -- Energy Efficiency Strategies for Hydronic Systems Through Intelligent Actuators PDF

Published Date:
2014

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The degradation of the difference between supply and return water temperature from design values is a condition found in many chilled and hot water distribution plants, leading to a significant waste of distribution and primary system energy. Here, several strategies aimed at preventing delta-T degradation are compared using simulations and field tests. Unnecessarily high flow through the heat exchanger (heating or cooling coil) is one cause of delta-T degradation. Limiting either the delta-T or the flow across the heat exchanger are two known approaches to reduce delta-T degradation on the primary side. A novel strategy, termed flow/delta-T limiting, is introduced and compared to the existing flow and delta-T limiting strategies. It is found that flow limiting is superior when either inlet air or water temperature is fluctuating. Conversely, delta-T limiting is superior when either entering air humidity or airflow rate is fluctuating. Because the numerous variables impacting heat exchanger behavior are typically changing simultaneously, the question arises which strategy is best? Through simulation studies it has been shown that flow/delta-T limiting is the preferred strategy that provides results falling between the flow and delta-T limiting approaches while maintaining acceptable heat exchanger performance. The different approaches have been applied to data sets acquired on two university campuses with the field tests supporting the simulation results.


File Size : 1 file , 2.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-NY-14-C073
Published : 2014

History


Related products


Best-Selling Products

AHRI 1010-94
Published Date: 01/01/1994
Self-Contained, Mechanically Refrigerated Drinking-Water Coolers
$7.5
AHRI 1060-00
Published Date: 01/01/2000
Rating Air-to-Air Energy Recovery Ventilation Equipment
$13.5
AHRI 1060-01
Published Date: 09/01/2001
Rating Air-to-Air Heat Exchangers for Energy Recovery Ventilation Equipment
$8.7
AHRI 1060-2005
Published Date: 2005
Performance Rating of Air-To-Air Heat Exchangers for Energy Recovery Ventilation Heat Equipment
$6.9
AHRI 1060-2011
Published Date: 2011
Performance Rating of Air-To-Air Heat Exchangers for Energy Recovery Ventilation Heat Equipment (I-P) (AHRI)
$6.9
AHRI 1060-2013
Published Date: 2013
Performance Rating of Air-To-Air Heat Exchangers for Energy Recovery Ventilation Heat Equipment (I-P) (AHRI)
$6.9